– 14 –
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
SYSTEM OVERVIEW
About the Display and Indicators
Display Definitions (for other displays, see Trouble Messages)
ALARM
AWAY
INSTANT
STAY
FIRE
REC MESSAGE
BYPASS
FAULT
CHIME TEST
LOW BAT AC
ALARM: Appears when the system is armed and an intrusion has been detected (also appears
during a fire alarm or audible emergency alarm). Accompanied by the protection zone
that is in alarm.
AWAY: All burglary zones, interior and perimeter, are armed.
INSTANT: Entry delay is turned off.
STAY: Perimeter burglary zones, such as protected windows and doors, are armed.
UL
ULUL
UL
LYNXR-2 Series is not intended for UL985 Household Fire applications unless a 24-hour backup
battery (P/N LYNXRCHKIT-HC) is installed.
FIRE: Appears when a fire alarm or fire fault is present. Accompanied by a display of the
zone that is in alarm.
LOW BAT: Low battery condition in a wireless sensor (if zone number is displayed) or low system
battery (if no zone number is displayed). If 00 is displayed, a wireless keypad (5827)
has a low battery condition.
AC: Appears when AC power is present. If not displayed, the system is operating on
backup battery power.
CHIME: Appears when the Chime feature is activated.
TEST: Appears when the system is in Test mode.
LYNXR-2SIA blinks during the last 5 minutes of test.
REC: Appears when the system is in Recording mode.
MESSAGE: Appears when a message has been recorded and has not yet been played back.
BYPASS: Appears when one or more burglary protection zones have been bypassed.
FAULT: Appears at any time a malfunction is discovered in the system; or any time an open
is detected in a fire zone; or when a fault in a day/night burglary zone is discovered
during a disarmed period. Accompanied by a display of the zone number in trouble.
PH: Appears in place of the clock when the speaker phone mode is active.
PC: Appears during a remote phone control session.
LED Meanings
ARMED LED: ON = System armed
(Red) OFF = System disarmed
Blinking = System armed, but a fault exists
Blinking alternately with READY LED = AVM (VOX or Talk) or speaker phone mode
is active
READY LED: ON = System disarmed, ready to arm
(Green) OFF = System armed
Blinking = System disarmed, not ready to arm (a fault exists)
Blinking alternately with ARMED LED = AVM (VOX or Talk) or speaker phone
mode is active.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNXR-2 Series Security System and is the answer not in the manual?

Honeywell LYNXR-2 Series Security System Specifications

General IconGeneral
BrandHoneywell
ModelLYNXR-2 Series Security System
CategorySecurity System
LanguageEnglish

Related product manuals