NFS-320SYS Intelligent Addressable Fire Alarm Control Panel
General
The NFS-320SYS intelligent Fire Alarm Control Panel is part of the
ONYX
®
Series of Fire Alarm Controls from NOTIFIER.
As a stand-alone small-to-large system, or as a large network, the
ONYX Series of products meet virtually every application require-
ment.
The modular design of the ONYX Series makes system planning
easier. The panel can be configured with just a few devices for small
building applications, or networked with many devices to protect a
large campus or a high-rise office block. Simply add additional
peripheral equipment to suit the application. Wireless fire protection
can be added with the SWIFT wireless gateway and devices.
NOTE: Unless called out with a version-specific “E” at the end of the part
number, “NFS-320SYS” refers to models NFS-320SYS and NFS-
320SYSE; similarly, “CPU-320SYS” refers to models CPU-320SYS and
CPU-320SYSE.
ONYX® Series panels integrate with the Connected Life Safety Ser-
vices (CLSS) platform through the CLSS Gateway, providing
connectivity to central station, cloud, and mobile applications. (See
HON-62034.) This cloud-based functionality provides reliable pro-
tection and remote monitoring of the system, reduced manual data
entry, and reporting.
Features
Certified for seismic applications when used with the appropriate
seismic mounting kit.
Approved for Marine applications when used with listed compati-
ble equipment. See DN-60688.
One isolated intelligent Signaling Line Circuit (SLC) Class A, B,
or X.
Wireless fire protection using SWIFT Smart Wireless Integrated
Fire Technology. See DN-60820.
Up to 159 detectors and 159 modules per SLC; 318 devices max-
imum.
Detectors can be any mix of photo, thermal, or multi-sensor;
wireless detectors are available for use with the FWSG(A).
Modules include addressable pull stations, normally open con-
tact devices, two-wire smoke detectors, notification, or relay;
wireless modules are available for use with the FWSG(A).
Standard 80-character display.
Network options:
High-speed network for up to 200 nodes (N16e/x, NFS2-3030,
NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM,
ONYXWorks, NFS-3030, NFS-640, and NCA.
Standard
network for up to 103 nodes (N16e/x, NFS2-3030,
NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM,
ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-
300/400, AFP-1010, and AM2020. Up to 54 nodes when DVC-
EM is used in network paging.
6.0 A power supply with four Class A/B built-in Notification Appli-
ance Circuits (NAC). Selectable System Sensor, Wheelock, or
Gentex strobe synchronization.
Built-in Alarm, Trouble, Security, and Supervisory relays.
VeriFire
®
Tools online or offline programming utility. Upload/
Download, save, store, check, compare, and simulate panel data-
bases. Upgrade panel firmware.
Autoprogramming and Walk Test reports.
Multiple central station communication options:
Standard UDACT
Internet
Internet/GSM
80-character remote annunciators (up to 32).
EIA-485 annunciators, including custom graphics.
Printer interface (80-column and 40-column printers).
History file with 800-event capacity in nonvolatile memory, plus
separate 200-event alarm-only file.
Alarm Verification selection per point, with automatic counter.
Presignal/Positive Alarm Sequence (PAS).
Silence inhibit and Auto Silence timer options.
NAC coding functions:
March time.
Temporal.
California two-stage coding.
Canadian two-stage.
Strobe synchronization.
Optional cloud connectivity for remote off site monitoring through
CLSS (see HON-62034)
Monitor multiple buildings through one off-campus central station,
and report through the CLSS Gateway
Optional remote programing through CLSS
Field-programmable on panel or on PC with VeriFire
®
Tools pro-
gram check, compare, simulate.
Full QWERTY keypad.
Battery charger supports 18 – 200 AH batteries.
Non-alarm points for lower priority functions.
Remote ACK/Signal Silence/System Reset/Drill via monitor mod-
ules.
Automatic time control functions, with holiday exceptions.
Extensive, built-in transient protection.
Powerful Boolean logic equations.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Notifier NFS-320SYS and is the answer not in the manual?

Honeywell Notifier NFS-320SYS Specifications

General IconGeneral
BrandHoneywell
ModelNotifier NFS-320SYS
CategoryFire Alarms
LanguageEnglish

Related product manuals