PID-95P, PID-95
Point Identification Device
APPROVED
MEA
Approved
7300-1703:0135
SIGNALING
S521
FM
Description
The Gamewell-FCI PID-95P addressable point identifica-
tion device is the interface between the non-powered, nor-
mally open, dry-contact devices and Gamewell-FCI’s 600
Series and ILI95-E3 Series
®
of analog addressable Fire
Alarm Control Panels (FACPs). Point identification devices
monitor a single Style B circuit, and are designed for con-
cealed mounting in an electrical backbox. The PID-95P can
be surface or flush mounted and has a visible LED for
alarm/annunciation.
Operation
The point identification device connects to the Signaling
Line Circuit (SLC) via two wires. The PID-95 will monitor,
via a two-wire supervised SLC circuit, contact-type devices
such as a waterflow switch or a manual station. Upon acti-
vation of the monitored device, the PID-95 will report its
address to the 600 Series and ILI95-E3 Series FACP via
the analog SLC. The control panel will then activate into all
alarm programmed outputs related to the PID-95.
Programming
The PID-95 is programmed by setting a single DIP switch,
easily accessible on the device’s printed circuit board. The
DIP switch sets the address of the device and the priority
interrupt (DIP SW #8). All other programming is accom-
plished at the FACP through a laptop computer or the con-
trol panel operator’s display. (600 Series only).
Standard Application
The PID-95 is the interface between the dry-contact type
devices and the SLC of the control panel. The PID-95 is a
means of connecting and identifying monitor points without
the use of conventional input modules at the main control
panel. The use of PID-95s can dramatically reduce the field
wiring required on many projects.
E3 Series® is a registered trademark of Honeywell International Inc.
Microsoft® Windows® is a registered trademark of Microsoft® Corporation.
Features
Compatible with the Gamewell-FCI, 600 Series and
ILI95-E3 Series Systems
Monitors dry-contact devices
Includes an LED for alarm annunciation
Field programmable
Provides priority interrupt
Offers a plate-mounted version available for surface or
flush mounting in a 4" x 4.688" (10.16 cm x 11.908 cm)
double gang backbox or 4” x (10.16 cm) square backbox
PID-95
PID-95P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell PID-95P and is the answer not in the manual?

Honeywell PID-95P Specifications

PID-95P

Power IconPower
standby current0.0005A, 0.0008A
alarm current0.0015A
Operating Environment IconOperating Environment
operating temperature32°F to 120°F (0°C to 49°C)
relative humidity93%, non-condensing
Weight and Dimensions IconWeight and Dimensions
dimensions4" x 4.688" (10.16 cm x 11.908 cm)

PID-95

Power IconPower
standby current0.0005A, 0.0008 A
alarm current0.0015A
Operating Environment IconOperating Environment
operating temperature32°F to 120°F (0°C to 49°C)
relative humidity93%, non-condensing
Weight and Dimensions IconWeight and Dimensions
dimensions4" (10.16 cm) square backbox