Opening the Chemcassette
®
cartridge door
Figure 8: Opening the Chemcassette cartridge door
Loading a Chemcassette
®
cartridge
Figure 9: Loading a Chemcassette cartridge
1. Navigate to the “Change Chemcassette” menu option.
2. Follow the on-screen instructions to install or change the cartridge.
3. Remove the paper optics card from the gate.
4. Insert the Chemcassette cartridge in the detector (it will t in only one
orientation). The take-up spindle rotates slightly to allow the cartridge
to snap into place easily.
5. Close the cover.
6. A summary of the current conguration will be displayed. Select
either to enter monitor mode or to remain out of monitor mode (i.e.,
idle).
Removing a Chemcassette
®
cartridge
1. Navigate to Maintenance > Open/Close gate.
2. Select “Open Gate.”
3. Remove the cartridge.
4. Select “Close Gate.”
5. Inert the optics card in the gate if the detector will be stored or
transported.
Changing the selected gas
1. While out of monitor mode, navigate to Set-up > Monitoring > Gas.
2. Select “Current gas” and pick the desired gas from the selection box
3. Select “Save.”
Entering monitor mode
From the main menu, navigate to the “Monitor Mode” option and select
“Enter monitor mode.”
1. If a Chemcassette cartridge has been installed, the detector will enter
Monitor Mode.
2. If a Chemcassette cartridge has not been installed, a user with
the necessary passcode can inititate the Chemcassette wizard.
Otherwise, the detector will not enter monitor mode.
Wiring and tubing
The SPM Flex detector has exible installation options to allow the user to
select the one most suitable for a specic application. The 4-20 mA output
is a three-wire connection that is congurable as sink, source, or isolated.
The detector is equipped with three relays.
Sample Tubing Specications
Description Maximum
Inlet
Tubing length, ft. (m) 100 (30) 66 (20) 33 (10) 0
Transport time (sec) 19 13 7 1
Flow rate (cc/min.) 700-1200 (flow is set and controlled per calibration)
Tubing OD, in. (mm) 0.25 (6.35)
Tubing ID, in. (mm) 0.125 (3.18)
Outlet
Tubing length, ft. (m) 100 (30)
Tubing OD, in. (mm) 0.25 (6.35)
Tubing ID, in. (mm) 0.188 (4.76)
The overall maximum load on the pump between the inlet and the exhaust should not exceed 10 inches H
2
O.
Use Teon Fluorinated Ethylene Polymer (FEP) tubing to ensure proper
sample transport.
NOTE
!
The SPM Flex detector is supplied with the standard Ethernet, power,
and communications connectors installed. The Ethernet connector can
be removed and provides a 1-inch conduit port which allows a direct
connection to the PCB communication terminals. Refer to the
Wiring and
tubing
section of the user manual for more information.
Attaching the shoulder strap
If the shoulder strap is to be used with a portable detector, attach its
spring clips to each of the rings on the detector’s handle.
Product label
Have questions?
Honeywell Analytics
405 Barclay Boulevard
Lincolnshire, Ilinois 60069
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Main Menu
Login/Logout
Reset Alarms & Faults
Reset all
Silence
audio alarm
Monitor Mode
Enter
monitor mode
Out of
monitor mode
Change Chemcassette
Review Mode
Event
History
Gas
Settings
Network
Additional
Status
Output
State
SoftwareTrend/Plot
Chem-
cassette
Maintenance
Inhibit
Summary
4-20 mA
Current Loop
Flow Char-
acterization
Open/Close
Gate
Update
Program
Setup
General
Monitoring Latching
Outputs Network
Configuration
Manager
Security
Test
Power Off
Optics
Verification
Simulate
Force
Relay
Force
4-20 mA
Figure 10. SPM Flex menu map
Menu Map
Figure 11. SPM Flex label

Other manuals for Honeywell SPM Flex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell SPM Flex and is the answer not in the manual?

Honeywell SPM Flex Specifications

General IconGeneral
BrandHoneywell
ModelSPM Flex
CategorySecurity Sensors
LanguageEnglish

Related product manuals