Page #1 background image
® U.S. Registered Trademark
Copyright © 2004 Honeywell International Inc. • • All Rights Reserved
INSTALLATION INSTRUCTIONS
69-1711
T822 Thermostat
STEP 1. PREPARE FOR
INSTALLATION
The T822 Thermostat controls 2-wire, 15 Vac to 30 Vac,
gas, oil or electric heating-only systems.
The T822 Thermostat is not suitable for:
cooling systems
heating-cooling systems
3-wire electric heating systems
If you are unsure which thermostat model is right for your
system, visit www.honeywell.com/yourhome
or call
Honeywell Customer Care at 1-800-468-1502.
1. Check that the following components are included:
Thermostat
Two one-inch screws
Installation Instructions
2. Required tools:
Slotted screwdriver
Drill
Drill bit (1/16 in.)
Needle nose pliers
Level
Pencil
STEP 2. REMOVE OLD
THERMOSTAT
1. Turn power off to the system at the furnace or at
the fuse/circuit breaker panel.
2. Remove cover on the old thermostat. If the cover
does not easily pull off, remove any screws that
may fasten the cover to the thermostat.
3. Locate the heat anticipator scale and the heat
anticipator lever on the old thermostat (see Fig. 1).
Fig. 1. Heat anticipator on old thermostat (example).
4. Record the number that the heat
anticipator lever points to on the heat
anticipator scale.
NOTE: If you cannot find the heat anticipator setting on
your thermostat, you can use a standard setting
for your type of system when you reach Step 5.
Set Heat Anticipator On New Thermostat.
5. Remove any screws that hold the thermostat to the
wall and pull the thermostat away from the wall.
6. Remove the two wires from the old thermostat and
wrap them around a pencil to keep them from fall-
ing back into the wall (see Fig. 2). If there are more
than two wires connected to your old thermostat,
do not remove the wires. Visit www.honey-
well.com/yourhome or call 1-800-468-1502 for fur-
ther assistance with the installation.
Fig. 2. Pull wires through wall opening.
M21192
OLD THERMOSTAT HEAT
ANTICIPATOR SCALE
HEAT ANTICIPATOR LEVER
TYPI
CA
L LO
CA
TIO
N
OF
H
E
A
T
AN
TI
C
IP
A
TO
R
S
CA
LE
AND
LEVE
R
WIRES
THROUG
H
WALL
OPENING
M1964
5

Other manuals for Honeywell T822

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell T822 and is the answer not in the manual?

Honeywell T822 Specifications

General IconGeneral
BrandHoneywell
ModelT822
CategoryThermostat
LanguageEnglish

Related product manuals