PRODUCT DATA
® U.S. Registered Trademark
Copyright © 2000 Honeywell • • All Rights Reserved
T8011R Programmable
Heat Pump Thermostat
APPLICATION
The T8011R Heat Pump Thermostat provides 24 Vac control
of a two-stage heating and one-stage cooling heat pump
system with manual changeover from heat to cool. First stage
heating and cooling cycle rates are fixed at 3 cph. Second
stage heating cycle rate is selectable at 1, 3, 6 or 9 cph.
Temperature indication can be set for °F or °C.
The T8011R Heat Pump Thermostat is powered directly
through the system transformer.
FEATURES
Attractive styling complements any decor to the
homeowners delight.
Preprogrammed for your convenience.
Program up to four time periods and temperature
setpoints to complement your lifestyle.
Programs are permanently held in non-volatile
memory in the event of a power failure.
Indefinite setpoint temperature hold for added comfort
and energy savings.
Ease-of-use means fewer homeowner questions and
increased homeowner satisfaction.
Large temperature display for quick easy readability.
Conveniently sized thermostat (5-1/2 x 3-1/2) with
optional decorator cover plates (7-3/8 x 5-3/4) make it
easy to install in a variety of locations.
Keys are located by the display for easy access.
FAN and SYSTEM switches are located on the lower
edge to eliminate accidental setting changes.
Easy installation, setup and system checkout saves
time and increases installer productivity.
Manual changeover from heat to cool eliminates
unexpected system operation.
°F or °C temperature display for added model
flexibility.
Cooling cycle rate is fixed (3 cph), the standard setting
for compressors, for speedy installation.
Selectable 2nd stage heating cycle rate (1, 3, 6 or
9 cph). First stage heating cycle rate is fixed at 3 cph.
Setpoints are permanently held in non-volatile
memory (no batteries required) and retained during
power outages for increased installer and homeowner
convenience.
Em. Ht. and Aux. Ht. indicators let the homeowner
know when these modes are active.
Contents
Application .......................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Installer Setup ..................................................................... 4
Operation ............................................................................ 6
Checkout ............................................................................. 9
Troubleshooting .................................................................. 10
68-0196-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell TRADELINE T8011R and is the answer not in the manual?

Honeywell TRADELINE T8011R Specifications

General IconGeneral
BrandHoneywell
ModelTRADELINE T8011R
CategoryThermostat
LanguageEnglish

Related product manuals