B
A
Powered hand tool
Agitator brush roll
replacement
When agitator brush roll brushes are worn,
the brush roll should be replaced.
Ask for HOOVER part no. 48414088.
How to replace
Disconnect cleaner from electrical
outlet.
1. Remove tool from hose and turn it so bot-
tom faces up. Press the latches on either
side of tool and remove bottom plate (A).
2. Unscrew the two Philips screws and
remove belt guard (B).
3. Remove agitator including end plates (C)
and discard.
4. Inspect belt to ensure that it is in good
condition. If belt is cracked, gouged or bro-
ken, replace it (see following section).
5. Insert brush roll through belt and position
belt over gear teeth (D) on brush roll.
3-24
6. With curved ends down, slide end plates
(C) of brush roll into slots (E) on tool.
3-25
7. Replace belt guard (B) making sure not to
pinch brush bristles in guard.
Turn agitator, making sure it rotates freely.
Replace and tighten screws.
3-26
8. To replace bottom plate (A), insert the four
tabs on edge of bottom plate into slots on
front of tool.
Pivot bottom plate down and snap closed.
C
D

Table of Contents

Other manuals for Hoover S3670

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hoover S3670 and is the answer not in the manual?

Hoover S3670 Specifications

General IconGeneral
BrandHoover
ModelS3670
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals