INTRODUCTION
The
HP
8756A
scalar
network
analyzer
and
the
HP
8350B
sweeper
provide
a
powerful
scalar
analysis
system
for
RF
and
microwave
reflection
and
transmission
measurements.
However,
some
applications
require
great-
er
frequency
accuracy
and
/
or
stabili
ty
than
the
HP
8350B
can
provide
.
Adding
the
HP
53448
source
synchronizer
to
this
system
can
greatly
enhance
the
frequency
accuracy
and
stability
of
scalar
measurements
by
phase
locking
the
sweeper
output
to
a
time
base
which
is
stable
to
within
5
parts
in
ICE-IO
per
day.
This
note
descr
ibes
the
local
operation
of
the
HP
8756A
/
8350B
/
5344S
system
and
provides
examples
of
a
number
of
measurement
configurations.
It
is
intend-
ed
to
supplement
the
information
available
in
the
Operating
and
Service
Manuals
of
the
various
instruments
and
several
useful
product
notes.
Appendix
I
contains
a
list
of
these
documents
and
their
HPpart
numbers
.
The
HP
53448
system
consists
of
two
parts
, a
microwave
frequency
counter
(either
an
HP
5342A
or
an
HP
5343A)
and
the
HP
5344A
microwave
source
synchronizer.
This
system
can
phase
lock
a
signal
source
,
in
this
case
the
sweeper
,
with
1 Hz
resolution
ov
er
a
broad
frequency
range
(500
MHz-18
GHz
with
the
HP
5342A
counter
and
500
MHz
- 26 . 5
GHz
for
the
HP
5343A
counter)
.
The
HP
53445
also
provides
useful
features,
such
as
subharmonic
/
offset
locking
and
AUTO
LOCK.
Subharmonic
/
offset
locking
can
simplify
the
RF
measurement
hardware
.
AUTO
LOCK
can
be
used
to
set
up
the
sweeper
automatically
while
locking
.
These
fu
n
ctions
will
be
described
in
later
sections.
S
ETT
I
NG
OP MEASUREMENTS
Synchronized
measurements
can
be
made
in
four
modes:
CW
for
single
frequency
measurements,
CF
/
6F
and
STRT/
STOP,
both
for
narrowband
locked
sweeps
up
to
40
MHz
wide,
and
LK
/ R
for
wideband
"lock
and
roll"
sweeps.
This
section
describes
in
detail
how
to
set
up
and
perform
measurements
in
all
four
measurement
modes
(
CW,
CF
/
L'::..F,
STRT/
STOP,
LK
/ R)
with
a
basic
configu
ration
using
the
8756
System
Interface,
normal
locking
and
MANUAL
LOCK
.
The
following
instructions
describe
how
to
set
up
the
hardware
for
measurements
in
our
basic
configuration.
1 . On
the
HP
5344A
rear
panel,
a)
Set
the
MODE
switch
to
the
"NORM"
position.
This
selects
normal
locking
mode
.
b)
Set
the
LOOP
BANDWIDTH
swi
tch
to
the
"
WE
"
position.
This
selects
wideband
locking
loop
bandwidth.
See
the
HP
53
445
Operating
and
Service
Manual
for
details.
3
8756
c)
Set
the
SYS
CONT
switch
(top
switch
on
the
ADDRESS
DIP
switch)
to
the
"0"
position.
Thi
s
sets
up
the
MANUAL
LOCK
mode
.
If
this
switch
is
in
the
"I"
position
for
system
control
(used
in
AUTO
LOCK)
then
the
"CONT"
annunciator
will
appear
on
the
front
panel
of
the
HP
5344A.
2.
On
the
counter
,
set
the
time
base
switch
to
the
"INT"
position
.
This
selects
the
counter's
internal
time
base.
3.
Connect
the
HP-IB
cable
from
the
8756
System
Interface
to
the
HP
83505,
as
shown
in
figure
1.
HP
8756A
Scalar Network Analvzer
Synem
Interface
"-
. 1
0
"
;;:
I
-V
-
o
00
HP
83508
Sweep ChcillltOf
"'>r
:
-
.I
:
o 0
0
HP
53445 M
jcrow~ve
Source Synchronizer
f
:o
t
~
j
SYS
CaNT
Swi
tch
to
..
~
..
Figure
I.
Hp·IB conneCli
on
for MANUAL
LOCK.
4.
Connect
the
cables
for
the
control
signals
as
shown
in
figure
2.
In
any
mode
,
the
HP
8756A
requires
a
O-lOV
sweep
ramp
(SWEEP IN O- lOV)
and
a Z
axis
blanking
pulse
(POS Z
BLANK
)
for
the
display
.
The
sweep
times
are
determined
by
the
device
generating
the
sweep
ramp.
Figure
2
shows
the
system's
control
signals
,
includ-
ing
the
sweeps,
Z
axis
blanking,
and
the
sweep
trigger
.
Note
that
the
HP
8756A
display
inputs
,
SWEEP
IN
and
POS Z BLANK,
come
from
the
HP
5344A
SWEEP
OUT
and
Z AXIS
OUT
,
and
IF
Out
IF
In
'<0.
10
MHl
Std
Out
'"
HP
S344S
Swp
HP
8756A
Microwave
Trg·
Seal"
Network Analyzer
Sou
..
"
:
.1
ot
Synchronizer
'M
'. 1
pos
Z Blank
Z A,ds
out!f
0",
0
Sweep
In
0·
10
V Swp Out
-
000
Stop Sweep
FM
Input
I
POS Z
B181'1k
Z
AXil
In
~'!I'
.I:
Sweep
Out/
In
Swp
In
0
HP
83509
SWltep
05cil1ator
p
rogrammlng Connector (
HP
Part No. 8120
3545
)
·This
connection
is required only
in
lock
and
Roll measuremenu.

Other manuals for HP 8756A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8756A and is the answer not in the manual?

HP 8756A Specifications

General IconGeneral
BrandHP
Model8756A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals