REQUIRED TOOLS
1. Toner approved vacuum
2. A small screwdriver (common style)
3. A Phillips head screwdriver
4. Needle nose pliers
5. Flat blade (common) screwdriver
REQUIRED SUPPLIES
1. Color toner for use in the HP M452/477 series cartridges (check for standard or high yield)
2. New replacement chip (check color, standard or high yield)
3. New long life drum
4. New wiper blade
5. New developer roller (optional)
6. New PCR (optional)
7. New doctor blade (optional)
8. Good quality double-sided tape 1/8” wide. (3M Brand preferred)
9. Lint free cloths
10. Conductive grease
1. With the HP top label facing you, remove the spring from the
left side of the cartridge.
2. On the same side, using a flat blade screwdriver, pry out the
top of the end cap until you feel the weld give way.
HP PRO M452 / MFP 477 (CF410/11/12/13 A/X-HP 410 SERIES) TONER CARTRIDGE REMANUFACTUIRNG INSTRUCTIONS
© 2017 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.
UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact techsupport@uninetimaging.com
www.uninetimaging.com