HIDDEN AND ADVANCED FEATURES
Feature Where Found Description
PROGRAMMABLE SENSOR
OVERRIDE
Hold and turn to Start Times
Sets individual stations to ignore sensor shutdowns. Select stations with ◄ or ►, (use +/
) to change
to OFF to ignore sensor.
CYCLE AND SOAK
Hold + and turn to Run Times. Enter Cycle, press
PRG to set Soak
Sets max time a station can run at once, and minimum time it must wait before another cycle.
Divides run time into segments to prevent runo.
DELAY BETWEEN STATIONS
Hold and turn to Run Times
Inserts a delay (seconds or minutes) between stations in a run time, for slow valves or
recharging tanks.
H
IDE PROGRAMS
Hold and turn to Water Days
Use +/
to change from 4 to 1 to hide extra programs. 1 will show only program A,
start time 1. 4 will show all programs and start times.
CLIK-DELAY
Hold + and turn to O
Set number of days for watering to remain o, aer sensor has been activated and restored.
TOTAL RUN TIME
Turn to Run Times. Press when station 1 is shown,
PRG to select other programs.
Calculates and displays total of all run times in a program start time.
EASY RETRIEVE
Hold + and PRG to Save. Hold and PRG to Restore
Saves all program information to restore at a later time.
TOTAL RESET
Hold PRG and press RESET button.
Returns to factory defaults and erases watering schedule and settings.
QUICK CHECK
+, , , together, then +
Checks all stations for wiring problems.
TROUBLESHOOTING GUIDE
Display Possible Cause Solutions
DISPLAY SHOWS “ERR” WITH
NUMBER
Short in eld wiring, or bad solenoid.
Check eld wiring and valve solenoid. Press any button to clear ERR message.
DISPLAY SHOWS P “ERR”
Short in Pump/Master Valve wiring or solenoid.
Check wiring and solenoid at P/MV. Check specications for Pump Start Relay.
DISPLAY SHOWS SP “ERR”
SmartPort
®
error. Electrical noise is present near
connection to remote or other SmartPort device.
Move connections away from sources of electrical noise.
DISPLAY SHOWS WATERING BUT
NO WATER IS OCCURRING
Problem in eld wiring. Problem with solenoids. No
water pressure to system.
Check eld wiring (voltmeter). Check valve solenoid(s). Verify water source is open.
FROZEN OR GARBLED DISPLAY
Power surge
Reset controller.
RAIN SENSOR DOES NOT STOP
IRRIGATION
Jumper wire is not removed. Sensor switch in
BYPASS position.
Remove jumper wire on SEN terminals. Set sensor switch to Active position.
CONTROLLER SEEMS TO WATER
CONTINUOUSLY
Too many start times.
One Start Time operates all stations in a program. Remove unnecessary start times.
When this symbol is shown, the controller is now managed online with Hydrawise soware and the controller dial and buttons are inoperable. Set schedules, suspend zones, congure
sensors, and more with the Hydrawise application. Leave dial in RUN position to continue Hydrawise programming schedule.
For troubleshooting information:
https://hunter.direct/X2help
?
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer
or service agent or a similarly qualied person to avoid hazard.
© 2019 Hunter Industries Inc. Hunter, the Hunter logo, and all other trademarks are property of Hunter Industries, registered in the U.S. and other countries. | hunterindustries.com
RC-103 - QG -US 9/19
|For more information visit Thelandscapestore.com.au | (02) 9161 3939 |

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hunter X2 and is the answer not in the manual?

Hunter X2 Specifications

General IconGeneral
BrandHunter
ModelX2
CategoryController
LanguageEnglish

Related product manuals