16
9
Air compressor Head Bolts
- Torquing
The air compressor pump head bolts should
be kept properly torqued. Check the torques
of the head bolts after the rst ve hours of
operation.
Torque to 14-16 ft-lbs (19–21.7 Nm).
10
Additional Service
Disassembly or service of the air compressor
beyond what is covered in this manual is
not recommended. If additional service is
required, contact 1-888-43-HUSKY for further
assistance.
Maintenance (continued)
Storage
Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform scheduled
maintenance as necessary.
2. Drain water from air tank. See To Drain Tank under Operation.
WARNING: Water will condense
in the air tank. If not drained,
water will corrode and weaken
the air tank causing a risk of air
tank rupture.
Troubleshooting
Problem Possible Cause Solution
Compressor does
not run.
Tank has insufcient
pressure.
When the tank pressure drops, the
compressor will turn on to cut-in
pressure.
No electrical power. Verify wiring connection inside
pressure switch and terminal box
area.
Blown stop/house fuse. Replace the shop/house fuse.
Tripped shop/home
breaker.
Reset the shop/home breaker and
determine the underlying cause.
Thermal overload is open. Place the Auto/Off switch in the
“Off” position.
Allow the motor to cool.
Depress the red reset button on
the motor.
Place the Auto/Off switch in the
“Auto” postion to restart the
motor.