EasyManuals Logo
Home>IBM>Desktop>Personal System/2 65 SX

IBM Personal System/2 65 SX User Manual

IBM Personal System/2 65 SX
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
|
design
information
in
the
Hardware
Interface
Technical
Reference
-
|
Architectures
manual.
|
Output
Protection
|
A
short
circuit
placed
on
any
dc
output
(between
outputs
or
between
|
an
output
and
de
return)
latches
all
de
outputs
into
a
shutdown
state
|
with
no
damage
to
the
power
supply.
|
If
an
overvoltage
fault
occurs
(internal
to
the
power
supply),
the
|
power
supply
latches
all
de
outputs
into
a
shutdown
state
before
any
|
output
exceeds
130%
of
its
nominal
value.
|
If
either
of
these
shutdown
states
is
actuated,
the
power
supply
|
returns
to
normal
operation
only
after
the
fault
has
been
removed
and
|
the
power
switch
has
been
turned
off
for
at
least
ten
seconds.
|
Voltage
Sequencing
|
At
power-on
time,
the
output
voltages
track
within
50
milliseconds
of
|
each
other
when
measured
at
the
50%
points.
|
Power
Supply
Connectors
|
The
power
supply
provides
two
4-pin
connectors
for
internal
fixed
|
disk
drives.
These
connectors
can
be
extended
to
provide
power
to
|
more
than
one
internal
drive
as
long
as
the
total
power
does
not
|
exceed
the
specifications
shown
in
Figure
1-6
on
page
1-9.
i
Pin
Signal
1
+12
Vdc
2
DC
Return
3
DC
Return
4
+5
Vde
©
a
—+/|©
No
OO
Figure
1-8.
Voltage
Assignments
for
the
Internal
Drive
Power-Supply
Connectors
1-10
Model
65
System
Overview
October
1990

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Personal System/2 65 SX and is the answer not in the manual?

IBM Personal System/2 65 SX Specifications

General IconGeneral
BrandIBM
ModelPersonal System/2 65 SX
CategoryDesktop
LanguageEnglish

Related product manuals