20. On the console, press Enter on the Complete Device Concurrent Add display to indicate that the
drive is installed. The service indicator stops flashing and turns off for that drive slot.
21. If you are installing more than one drive, repeat the steps in this procedure until all drives are
installed.
Preparing the 5148-21L, 5148-22L, 8247-21L, 8247-22L, 8284-21A, or 8284-22A
system for operation after removing and replacing a drive with the power turned
on in Linux
Learn to prepare the system for operation after you replace a disk drive or solid-state drive (SSD) in a
system with the Linux operating system or Linux logical partition that controls the drive location
powered on.
To prepare the system for operation, complete the following steps:
1. To verify that the new disk drive or solid-state drive is operational, complete the following steps:
a. Log in as root user.
b. Type iprconfig on the command line of the Linux session and press Enter. The IBM Power RAID
Configuration Utility display is shown.
c. Select Display hardware status. The Display Hardware Status display is shown, similar to the
following figure.
P8HAL507-2
A
Figure 97. Replacing an SSD in an expanded function system
Disk drives or solid-state drives 95

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power System 5148-21L and is the answer not in the manual?

IBM Power System 5148-21L Specifications

General IconGeneral
BrandIBM
ModelPower System 5148-21L
CategoryServer
LanguageEnglish

Related product manuals