Table 69. Noise emissions
1, 2, 3
(continued)
Product description
Declared A-weighted sound power level,
L
Wad
(B)
Declared A-weighted sound pressure
level, L
pAm
(dB)
Model 7063-CR1 (1-
socket) at maximum
temperature with
acoustical doors
(front and rear), FC
EC08 and FC EC07,
installed.
7.9
4, 5
7.9
4, 5
63 63
Notes:
1. Declared level L
Wad
is the upper-limit A-weighted sound power level. Declared level L
pAm
is the mean A-
weighted emission sound pressure level that is measured at the 1-meter bystander positions.
2. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. 10 dB (decibel) equals 1 B (bel).
4. Under certain environments, congurations, system settings, and workloads, fan speeds are increased that
result in higher noise levels.
5. Notice: Government regulations (such as those prescribed by OSHA or European Community Directives)
might govern noise level exposure in the workplace and might apply to you and your server installation. This
IBM system is available with an optional acoustical door feature that can help reduce the noise that is
emitted from this system. The actual sound pressure levels in your installation depend upon various factors,
including the number of racks in the installation; the size, materials, and conguration of the room where
you designate the racks to be installed; the noise levels from other equipment; the room ambient
temperature, and employees' location in relation to the equipment. Further, compliance with such
government regulations also depends upon various extra factors, including the duration of employees'
exposure and whether employees wear hearing protection. IBM recommends that you consult with
qualied experts in this eld to determine whether you are in compliance with the applicable regulations.
Electromagnetic compatibility compliance: CISPR 22:2008; CISPR 32:2012, CNS 13438 (Taiwan); EN
55032:2012 (EU, Australia); EN 55024:2010 (EU); EN 61000-3-2:2014 (EU, Japan); EN 61000-3-3:2013
(EU); FCC, Title 47, Part 15 (USA); GB 9254-2008 (China); GB 17625.1-2012 (China); GB 17625.2-2007
(China); ГОСТ 30804.3.2-2013 (IEC 61000-3-2:2009) (EAEU); ГОСТ 30804.3.3-2013 (IEC
61000-3-3:2008) (EAEU); ГОСТ 30805.22-2013 (CISPR 22:2006) (EAEU); ГОСТ CISPR 24-2013 (EAEU);
ICES-003, Issue 6, January 2016 (Canada); KN 32:2015 (Korea); KN 35:2015 (Korea); TCVN 7189:2009
(Vietnam); VCCI, April 2015 (Japan)
Safety compliance: UL 60950-1, 2nd Edition, 2014-10-14; CAN/CSA C22.2 No. 60950-1-07, 2nd
Edition, 2014-10, IEC 60950-1:2005 (Second Edition); Am1:2009 + Am2:2013; EN 60950-1:2006 +
A1:2010 + A11:2009 + A12:2011 + A2:2013
Rack switch specications
Rack switch specications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Select the appropriate models to view the specications for your rack switch.
Site and hardware planning
67

Other manuals for IBM Power System L922

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Power System L922 and is the answer not in the manual?

IBM Power System L922 Specifications

General IconGeneral
BrandIBM
ModelPower System L922
CategoryPower Supply
LanguageEnglish

Related product manuals