17. Restore the previously saved configurations by using the copy command to copy the configuration
file in the USB drive to the running configuration.
switch(config)# opy usb1:configuration_file_name running-config
Note: If you have not inserted the standby supervisor module until now, do not insert it during
this step. Instead, wait until you complete this procedure before installing the standby supervisor
module.
18. Save the configuration in the startup configuration by using the copy running-config startup-
config command.
switch(config)# copy running-config startup-config
Installing a Switching Module
About this task
Use this procedure to install a switching module in the chassis.
Procedure
1. Before installing any modules in the chassis, we recommend installing the chassis in the rack. See the
Installing the “Installing the SAN384C-6 or SAN768C-6 Device on a Four-Post Rack or Cabinet” on
page 66.
2. Before installing any switching modules, install at least one supervisor module.
3. Choose a slot for the module and verify that there is enough clearance to accommodate any cables
or interface equipment that you want to connect to the module. If possible, place modules between
empty slots that contain filler panels.
4. Verify that the captive screws are tightened to 8 in-lb on all modules already installed in the chassis.
This ensures that the EMI gaskets are fully compressed and maximizes the opening space for the
module being installed.
5. If a filler panel is installed, remove the two Phillips pan-head screws from the filler panel and remove
the panel. To remove a currently installed module, see the “Removing a Switching Module” on page
114.
6. Press line card ejector buttons to open both side levers to fully open position.
7. Position the module in the chassis as follows:
a) Align the line card into the chassis card cage slots and push it in slowly. It is recommended to push
the center of line card face plate to push the line card in.
b) Continue to push in the line card slowly into the chassis until its rear connectors touch the mid-
plane surface and both ejector levers swing inward about 25 degrees. This indicates that the both
ejector lever jaws are now inside the chassis jaw cutouts and the card is ready to close the ejector
levers.
c) Once visually confirmed that both ejector levers are swung inward about 25 degrees, push in
both ejector levers simultaneously to fully insert the line card into the chassis until they are in a
mechanically locked position. Both ejector levers should be parallel to the line card face plate when
locked.
Note: Ensure that the ejector levers are fully closed before tightening the captive screws. Failure
to fully seat the module in the backplane connector can result in error messages.
d) Tighten the two captive screws on the supervisor module or switching module to 8 in-lb.
Chapter 3. Installing the IBM c-type SAN Device113

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM SAN192C-6 and is the answer not in the manual?

IBM SAN192C-6 Specifications

General IconGeneral
BrandIBM
ModelSAN192C-6
CategoryStorage
LanguageEnglish

Related product manuals