EasyManuals Logo

IBM System x3200 Installation Guide

IBM System x3200
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background image
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The server stops responding
during the hard disk drive
diagnostic test.
Remove the hard disk drive that was being tested when the server stopped
responding, and run the diagnostic test again. If the hard disk drive diagnostic test
runs successfully, replace the drive that you removed with a new one.
A hard disk drive was not
detected while the operating
system was being started.
Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic
tests again.
A hard disk drive passes the
diagnostic Fixed Disk Test but
the problem remains.
Run the diagnostic SCSI Attached Disk test (see “Running the diagnostic
programs” in the Problem Determination and Service Guide on the IBM System x
Documentation CD).
Note: Use the SCSI Attached Disk test for drives that are part of RAID arrays. Use
the Fixed Disk test for SATA drives that are not part of RAID arrays
Intermittent problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v When the server is turned on, air is flowing from the fan grille. If there is no
airflow, the fan is not working. This can cause the server to overheat and
shut down.
2.
Check the system/event error log (see “Error logs” in the Problem
Determination and Service Guide on the IBM System x Documentation CD).
Chapter 5. Solving problems 63

Table of Contents

Other manuals for IBM System x3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3200 and is the answer not in the manual?

IBM System x3200 Specifications

General IconGeneral
Form FactorTower
NetworkIntegrated Gigabit Ethernet
ProcessorIntel Xeon 3000 sequence, Intel Pentium Dual-Core processor, Intel Celeron processor
Processor CoresDual-Core
ChipsetIntel 3000
MemoryUp to 8GB DDR2
Memory Slots4
StorageSATA HDD
RAID SupportRAID 0, 1
Drive Bays4 internal 3.5-inch