v Redundant connection
The addition of an optional network interface card (NIC) provides a failover
capability to a redundant Ethernet connection. If a problem occurs with the
primary Ethernet connection, all Ethernet traffic that is associated with the
primary connection is automatically switched to the redundant NIC. If the
applicable device drivers are installed, this switching occurs without data loss
and without user intervention.
v Redundant cooling and power capabilities
The redundant cooling of the fans in the server enables continued operation if
one of the fans fails. The server supports up to two hot-swap power supplies,
which provide redundant power for many server configurations.
v ServeRAID support
The server supports ServeRAID controllers to create redundant array of
independent disks (RAID) configurations.
v Symmetric multiprocessing (SMP)
The server supports up to four multi-core Intel Xeon microprocessors. One or
more multi-core microprocessors provides SMP capability.
Reliability, availability, and serviceability
Three important server design features are reliability, availability, and serviceability
(RAS). The RAS features help to ensure the integrity of the data that is stored in
the server, the availability of the server when you need it, and the ease with which
you can diagnose and correct problems.
The server has the following RAS features:
v Advanced memory features:
Single-bit memory error detection
Single-bit memory error hardware correction
Multi single-bit memory error recovery and corrections
Uncorrectable error (UE) detection
Full array memory mirroring (FAMM) redundancy
Automatic failover recovery for UEs when FAMM is configured
Automated logical removal of failed DIMMs on reboots prior to replacement
Automatic address parity checking during writes and reads
v Automatic BIOS recovery (ABR) for UEFI
v Automatic error retry and recovery
v Automatic restart after a power failure
v Availability of microcode and diagnostic levels
v Integrated management module (service processor)
v Built-in, menu-driven electrically erasable programmable ROM (EEPROM) based
setup, system configuration, and diagnostic programs
v Built-in monitoring for fan, power, temperature, voltage, and power-supply
redundancy
v Error codes and messages
v Error correcting code (ECC) L2 cache and system memory
v Fault-resistant startup
v Hot-swap hard disk drives
v IBM Systems Director workgroup-hardware-management tool
v Information and light path diagnostics LED panels
v Integrated management module
v Service processor adapter for remote systems management
v Parity checking on the SAS bus and PCI Express buses
10 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Installation and User's Guide

Table of Contents

Other manuals for IBM System x3850 X5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3850 X5 and is the answer not in the manual?

IBM System x3850 X5 Specifications

General IconGeneral
BrandIBM
ModelSystem x3850 X5
CategoryServer
LanguageEnglish

Related product manuals