SPECIFICATIONS
• Input voltage : 230 V AC (50/60 Hz)
• Input current : 2.3 A
• Output voltage : 13.8 V DC±5%
• Max. output current : 25 A, 50% duty (1 min. ON/1 min. OFF)
• Dimensions : 111(W)×94(H)×287(D) mm (projections not included)
• Weight (approx.) : 3.0 kg
• Usable temperature range : –10˚C to +40˚C
q Make sure the [POWER] switches on the PS-
126 and transceiver are OFF.
w Connect the DC output cable of the PS-126
to the transceiver DC power input socket.
e Connect the AC power cable to an AC outlet
and the PS-126.
r Turn the PS-126 ON.
• “ I ” : ON (Power indicator lights red)
• “O” : OFF (Power indicator goes off)
t Turn the transceiver ON.
y To turn OFF the system, turn the transceiver
power OFF, then the PS-126 in sequence.
POWER PROTECTOR
The PS-126 has an output protection circuit.
When the + and _ pins are shorted, the PS-
126 stops functioning. In such a case, turn OFF
the PS-126, remove the source of the problem,
wait several seconds, then turn it ON again.
OPERATION
PANEL DESCRIPTION
Power SW
Power indicator
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-6720H-1EU Printed in Japan
© 2008 Icom Inc.
Printed on recycled paper with soy ink.