3Independent - User’s
Operation
Winter conditions - i.e. CH and DHW required.
Ensure the mode knob control (D) is set to winter ( )
The boiler will re and supply heat to the radiators but will give
priority to DHW on demand.
The DHW preheat will operate as described under ‘Summer
conditions’ during periods when there is no call for CH.
Summer conditions - i.e. DHW only required.
Set the mode knob control to Summer ( ).
Set the CH external controls to OFF.
Preheat will operate with the preheat switch (A) set to ON.
The boiler will re periodically for a few seconds to maintain the
DHW calorier in a preheated condition. The average time period
between ring is 90 minutes. This may vary considerably due to
the surrounding ambient temperature of the boiler. The boiler will
re whenever there is a demand for DHW.
The boiler preheat facility can be immobilised by turning the
preheat switch (A) to OFF. This will stop the boiler operating
for short periods. This facility is primarily provided for boiler
installations in a sensitive area (i.e. bedroom etc.)
Note. The pump will operate briey as a self-check once every 24
hours, regardless of system demand.

Domestic Hot Water
The DHW temperature is limited by the boiler controls to
64
o
C maximum at low draw-off rate, adjustable via the DHW
temperature control (B).
Due to system variations and seasonal temperature uctuations
DHW ow rates/temperature rise will vary, requiring adjustment
at the draw off tap : the lower the rate the higher the temperature,
and vice versa.
Central Heating
The boiler controls the central heating radiator temperature to a
maximum of 80
o
C, adjustable via the CH temperature control (C).
The Independent is a high efciency combination boiler which is
most efcient when operating in condensing mode.
The boiler will operate in this mode if the CH temperature control
(C) is set to the ‘e’ position (economy mode). This control should
be set to maximum for very cold periods.

When the Weather Compensation option is tted to the system
then the CH Temperature Control (C) becomes a method of
controlling room temperature. Turn the knob clockwise to
increase room temperature and anti-clockwise to decrease room
temperature. Once the desired setting has been achieved, leave
the knob in this position and the system will automatically achieve
the desired room temperature for all outside weather conditions.

Set the mode knob control to OFF
To relight the boiler
Repeat the procedure detailed in ‘To light the boiler’.
Frost protection
If no system frost protection is provided and frost is likely during
a short absence from home, leave the heating controls (if tted)
at a reduced temperature setting. For longer periods, the entire
system should be drained.
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
tted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.

The boiler controls will shut down the boiler in the event of
overheating. Should this occur, a fault code will be displayed.
Refer to fault chart.
Flame Failure
Should this occur a fault code will be displayed. Refer to fault
chart.
Approx. ow temperatures for the boiler thermostat settings are:
Knob Setting Flow Temperature
Minimum 40
o
C (104
o
F)
Maximum 64
o
C (147
o
F)
continued . . . . . .
Legend
A. Pre-heat On/Off
B. DHW Temperature Control
C. CH Temperature Control
D. Mode Control
E. Boiler Status
F. Burner ‘on’ Indicator
G. Pressure Gauge
H. Condensate Drain
J. Economy Mode
1 
G
H
A B E F C DJ

Other manuals for IDEAL C24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL C24 and is the answer not in the manual?

IDEAL C24 Specifications

General IconGeneral
BrandIDEAL
ModelC24
CategoryBoiler
LanguageEnglish

Related product manuals