ADVANCED FEATURES
F1 - LOW WATER PRESSURE 1. FILL SYSTEM TO 1.0 BAR
2. BLEED RADIATORS
F2 - FLAME LOSS 1. CHECK OTHER GAS APPLIANCES WORK
F3 - FAN FAULT 1. CONTACT INSTALLER
F4 - FLOW THERMISTOR FAULT 1. CONTACT INSTALLER
F5 - RETURN THERMISTOR FAULT 1. CONTACT INSTALLER
F6 - OUTSIDE SENSOR FAULT 1. CONTACT INSTALLER
F7 - LOW MAINS VOLTAGE 1. CONTACT ELECTRICITY PROVIDER
F9 - PCB FAULT 1. CONTACT INSTALLER
F0 - NO WATER FLOW THERMISTOR FAULT 1. CONTACT INSTALLER
FA - FLOW/RETURN REVERSED 1. CONTACT INSTALLER
c0 - PCB REPLACED 1. RESET BOILER
c2 - BOILER TYPE CARD FAULT 1. CONTACT INSTALLER
204796-6.indd 16 15/12/2011 14:34:25
back

Other manuals for IDEAL LOGIC+ Combi 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC+ Combi 24 and is the answer not in the manual?

IDEAL LOGIC+ Combi 24 Specifications

General IconGeneral
ModelLogic+ Combi 24
CategoryBoiler
Boiler TypeCombi
Fuel TypeNatural Gas
MountingWall-mounted
ERP RatingA
Output24 kW
Efficiency94%
Dimensions (H x W x D)700 x 395 x 278 mm
Max. Working Pressure3 bar
Central Heating Flow Temperature Range30-80°C
Warranty7 years