EN-8 22204911 Rev. E
Temperature
Around
Compressor
Viscosity @ 100°F
(37.8°C)
Viscosity
Grade
°F °C SUS Centistokes ISO SAE
< 40 < 4.4 150 32 32 10
40-80 4.4-26.7 500 110 100 30
80-125 26.7-51.0 750 165 150 40
If you use a petroleum-based compressor lubricant at start-
up and decide to convert to All Season Select later on, the
pump must be decarbonized and ushed before conversion.
Contact Ingersoll Rand for more information.
GASOLINE ENGINE COMPRESSORS
NOTICE
If you will be making connections to a remote battery,
the engine on the compressor must be equipped with
an alternator.
BATTERY. A 12 volt battery with a minimum current rating of
275 CCA (cold cranking amps) and minimum ampere-hour
rating of 24 Ah should be sucient for cranking most electric
start engines.
BATTERY CABLES. Refer to the following table for size and
length recommendations.
Cable Size (GA) Maximum Length
6 5’ (1.5 m.)
4 7’-2.5” (2.1 m.)
2 12’ (3.6 m.)
CONNECTION PROCEDURES:
1. Connect the battery positive (+) cable (A) to the starter
solenoid terminal (B).
Kohler Engine Battery (+) Positive cable connection point
Honda Engine Battery (+) Positive cable connection point
NOTE: Circuit Fuse location at (D). Electric Start will not work
if Fuse is blown. Unit can be rope started, however will not
charge battery if Fuse is blown.
INSTALLATION