Page #24 background image
132A
SAVE THESE INSTRUCTIONS
English
(132) MODEL CS8220/8230 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 06/29/2013
Page 24
TROUBLESHOOTING GUIDE
INSUFFICIENT
CHLORINE
INSUFFICIENT
COPPER ION
LEVEL
POOL IS STAINED
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
GREEN HAIR
• Insufficient operating hours of
the Saltwater System.
• The salt level in the pool water
is less than 2000ppm. This is
insufficient.
• Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
• Insufficient operating hours.
• The PH is too high.
• The bather load has increased.
•
Clogged or dirty copper electrode.
• Copper electrode defective.
• High copper ion concentration.
• Excessive calcium hardness is
present in pool water.
No power supply.
RCD/GFCI has not reseted.
• A power fuse has blown.
• LED failure.
• High copper ion concentration.
• Increase the daily Saltwater System
operating time. See “Operating Instructions”.
• Check the salt level with the Test Kit. Adjust
as needed. See “Salt & Pool Water Volumes”.
Use a pool cover when the pool is not in use
and/or when the unit is operating.
Increase the daily Saltwater System operating
time. See “Operating Instructions”.
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
Cover the pool with a pool cover for 2 days with
the device running and then test the water
using the test strips.
If the pool is clean and clear, add stabilizer to
the water and then test the water with the
device running.
Increase operating time per day. See
“Operating Instructions”.
Use PH decrease chemical to adjust,
contact your local pool chemical store.
Increase the operating time per day.
See “Operating Instructions”.
Remove the cell for inspection, clean it
if necessary. See “Maintenance”.
Contact Intex Service Center.
• Drain about 20% of the pool water and add fresh
water to decrease the copper ion concentration
below 0.2ppm.
• Add aluminum sulfate: 1000 liters water need
around 2g (1000 gals need 0.27 ounce) or
aluminum potassium sulfate: 1000 liters water
need around 3g (1000 gals need 0.4 ounce)
to pool.
Use a lemon based cleaning product (preferably
containing citric acid). Don’t scrub with aggressive
cleaning products because this might etch the
underlying surface.
Drain about 20 to 25% of the pool water and add fresh
water to decrease the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean the electrolytic
cell if necessary.
Plug the cell cord firmly into the cell
housing receptacle.
• Find out the switch and turn on.
Reset the RCD/GFCI.
Contact Intex Service Center.
• Drain about 20% of the pool water and
add fresh water to decrease the copper
ion concentration below 0.2ppm.
• Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
Use ‘Ultra-Swim’ shampoo, or shampoo
containing chelating agents.
PROBLEM CAUSE SOLUTION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intex Krystal Clear CS8230 and is the answer not in the manual?

Intex Krystal Clear CS8230 Specifications

General IconGeneral
BrandIntex
ModelKrystal Clear CS8230
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals