261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 05/25/2018
English
Page 24
SALT TABLE FOR COMMON NON-INTEX POOLS
SALT CALCULATION FORMULA FOR ALL POOLS
Salt Needed for Startup
(Lbs)
Salt Needed for Startup
(Kgs)
Salt Needed when
Low Salt Detected (Lbs)
Salt Needed when
Low Salt Detected (Kgs)
Water Capacity (Gals) x 0.025
Water Capacity (Liters) x 0.003
Water Capacity (Gals) x 0.0067 Water Capacity (Liters) x 0.0008
Water Capacity
Salt Needed for Startup
Salt Needed when Low Salt
Detected (CODE “91”)
(Gals) (Liters)
ECO20220-1/ECO20230-1 ECO15220-1/ECO15230-1 ECO20220-1/ECO20230-1 ECO15220-1/ECO15230-1
(Lbs) (Kgs) (Lbs) (Kgs) (Lbs) (Kgs) (Lbs) (Kgs)
2000 7500 50 20 50 20 10 5 10 5
4000 15000 100 45 100 45 25 10 25 10
6000 22500 150 65 150 65 40 20 40 20
8000 30000 200 90 - - 55 25 - -
8500 32000 - - 210 95 - - 55 25
10000 37500 250 110 - - 70 30 - -
12000 45500 300 135 - - 80 35 - -
14000 53000 350 160 - - 95 45 - -
OPERATING TIME TABLE FOR COMMON NON-INTEX POOLS
Water Capacity
Operating Time (hours)
at different ambient/air temperatures
(Gals) (Liters)
ECO20220-1/ECO20230-1 ECO15220-1/ECO15230-1
10 - 19°C
(50 - 66°F)
20 - 28°C
(68 - 82°F)
29 - 36°C
(84 - 97°F)
10 - 19°C
(50 - 66°F)
20 - 28°C
(68 - 82°F)
29 - 36°C
(84 - 97°F)
2000 7500 1 1 1 1 2 3
4000 15000 2 2 3 3 3 4
6000 22500 3 3 4 4 5 6
8000 30000
4
45 - - -
8500 32000 - - - 6 7 8
10000 37500 5 5 6 - - -
12000 45500 6 6 7 - - -
14000 53000 7 7 8 - - -
CYANURIC ACID TABLE FOR COMMON NON-INTEX POOLS
Water Capacity
Cyanuric Acid Needed for Startup 0.03g/L (30ppm)
(Gals) (Liters)
ECO20220-1/ECO20230-1 ECO15220-1/ECO15230-1
(Lbs) (Kgs) (Lbs) (Kgs)
2000 7500 0.5 0.23 0.5 0.23
4000 15000 1.0 0.45 1.0 0.45
6000 22500 1.5 0.68 1.5 0.68
8000 30000 2.0 0.90 - -
8500 32000 - - 2.13 0.96
10000 37500 2.5 1.13 - -
12000 45500 3.0 1.37 - -
14000 53000 3.5 1.59 - -