18 Installation instructions SAF-MI-LBK-SBV-multi-v2.0-print-26000041 |© 2020-2021 Inxpect SpA
LBK-C22 safety outputs terminal block
Symbol Description
COM Common safety output 1
NO Relay output normally open
COM Common safety output 2
NO Relay output normally open
Note: the operating temperature of the cables must be at least 105 °C.
Note: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm (5 lbs in).
LBK-C22 auxiliary outputs terminal block
Symbol Description
COM Common auxiliary output 1
NO Relay output normally open
COM Common auxiliary output 2
NO Relay output normally open
Note: the operating temperature of the cables must be at least 80 °C.
Note: use only copper wires with a minimum gauge of 18 AWG and a torque of 0.56 Nm (5 lbs in).