EasyManuals Logo
Home>Inxpect>Radar>SBV System Series

Inxpect SBV System Series User Manual

Inxpect SBV System Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
42
SBV System Series| Instruction manual v1.2 DEC 2021 |SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
5. Sensor position
Contents
This section includes the following topics:
5.1 Basic concepts
42
5.2 Sensor field of view 43
5.3 Dangerous area calculation 45
5.4 Calculation of range of distances 46
5.5 Sensor position recommendations 47
5.6 Installations on moving elements 48
5.7 Outdoor installations 49
5.1 Basic concepts
5.1.1 Determining factors
The sensor installation height and inclination depend on the optimum position of the sensor. The optimum
position of the sensor depends on what follows:
l sensor field of view
l depth of the dangerous area (and therefore the detection field)
l the presence of other sensors
5.1.2 Sensor installation height
The installation height (h) is the distance between the center of the sensor and the ground or reference plane of
the sensor.
5.1.3 Sensor inclination
Sensor inclination is the rotation of the sensor around its x-axis. Inclination is defined as the angle between a line
perpendicular to the sensor and a line parallel to the ground. Three examples are presented as follows:
l sensor tilted upwards: α positive
l straight sensor: α = 0
l sensor tilted downwards: α negative

Table of Contents