8.2.3 Power supply terminal block
Note: connector front view.
Symbol Description
V- GND
Earth
V+ + 24 V dc
Note: the maximum operating temperature of the
cables must be at least 70 °C.
Note: use only copper wires with a minimum gauge
of 18 AWG and a torque of 0.62 Nm (5,5 lbs in).
8.2.4 CAN bus terminal block
Symbol Description
+ + 12 V dc output
H CAN H
L CANL
- GND
Note: the maximum operating temperature of the
cables must be at least 70 °C.
8.2.5 Connectors M12 CAN bus
Male connector Female connector
Pin Function
1 Shield, to be connected to ground circuit
power supply terminal block of the control
unit.
2 + 12 V dc
3 GND
4 CAN H
5 CANL
8. Technical references
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
83