EasyManuals Logo
Home>ITech>Power Supply>IT6821

ITech IT6821 User Manual

ITech IT6821
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Quick Start
Copyright © Itech Electronic Co., Ltd. 11
Current Output Checkout
The following steps check basic current functions with a short across the power
supply’s output.
1. Turn on the power supply.
2. Disable the output.
Press [On/Off] key to ensure that the output is disabled. The OFF
annunciator is turned on.
3. Connect a short across (+) and (-) output terminals with an insulated test
lead.
Use a wire size sufficient to handle the maximum current.
4. Enable the output.
Press [On/Off] key to ensure that the output is enabled. The OFF
annunciator is turned off.
5. Adjust the voltage value to 1.0 volt.
Adjust the voltage to 1.0 volt to ensure the power supply is in CC operation
mode. The CC annunciator will turn on.
6. Adjust the current value.
Set some different voltage values, then wait till the Meter mode to check if
the VFD displayed current value is the same as the set voltage value, and
to check if the VFD displayed voltage value is nearly zero.
7. Ensure that the current can be adjusted from zero to the full rated value.
8. Turn off the power supply and remove the short wire from the output
terminals.

Other manuals for ITech IT6821

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6821 and is the answer not in the manual?

ITech IT6821 Specifications

General IconGeneral
BrandITech
ModelIT6821
CategoryPower Supply
LanguageEnglish

Related product manuals