EasyManuals Logo
Home>ITech>Test Equipment>IT8512C+

ITech IT8512C+ User Manual

ITech IT8512C+
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Functions and Characteristics
Copyright © Itech Electronic Co., Ltd. 41
VON LATCH MODE
In Latch mode, as before, the load will turn on only when the voltage
exceeds VON setting, but once on, it will now stay on, even if the voltage
drops to zero.
3.13 Protection Function
IT8500+ series electronic load supports the following protection function:
Over voltage protection (OVP)
Over current protection (OCP)
Over power protection (OPP)
Over temperature protection (OTP)

Table of Contents

Other manuals for ITech IT8512C+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8512C+ and is the answer not in the manual?

ITech IT8512C+ Specifications

General IconGeneral
BrandITech
ModelIT8512C+
CategoryTest Equipment
LanguageEnglish

Related product manuals