Local water conditions may require treatment of the water to inhibit scale formation, improve taste
and clarity. If you are installing a water filter system, refer to the installation instructions supplied
with the filter system.
Pressure should be between 0.1MPa and 0.6MPa (1 and 6 bar). If pressure overpasses such values,
install a pressure regulator.
The water connection needs to be dedicated (only piece of equipment hooked to the water line).
Water line from the water valve to the ice machine needs to be ¼” nominal ID tubing.
ATTENTION: The machine shall be plumbed (with adequate backflow protection) according to
applicable Federal State and local regulations.
2.6.-DRAIN CONNECTION
2.6.1.- GRAVITY DRAIN
Drainage should be located lower to the machine level, at 150mm minimum.
It is convenient that the drain hose is 1,18” (30mm) inside diameter and with a minimum gradient
of 3cm/metre, see figure.
2.6.2.- DRAIN FORCE CONNECTION
This version of drain force allows an installation of the machine where the drain can be located 30
meters horizontally and 1.5 meters high from the machine's water outlet.
Correct
Incorrect
Incorrect

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITV ICE MAKERS NG Series and is the answer not in the manual?

ITV ICE MAKERS NG Series Specifications

General IconGeneral
BrandITV ICE MAKERS
ModelNG Series
CategoryIce Maker
LanguageEnglish

Related product manuals