It is the responsibility of the installer/owner to ascertain
compliance with specific local regulations prior to installa-
tion.
Jacuzzi Europe S.p.A. gives no guarantee in this respect
and refuses all responsibility regarding compliance of the
installation carried out.
Technical Features
The Premium spas feature a single-phase power supply (220-
240 V). All electro-mechanical parts and pipes are enclosed.
The J-210 is equipped with 1 two-speed pump, whilst the J-
235/245/275 are equipped with 2 pumps.
The J-315, J-325 model is equipped with 1 two-speed pump
for hydromassage, the J-335, J-345, J-355, J-365, J-375, J-385 , J-
575, J-585 and J-LXL models have 2 pumps; all models are also
equipped with a circulation pump.
The models of the J-400 range have 1-2-3 hydromassage
pumps and a circulation pump.
Maximum absorption of the system
The electrical system that powers the spa must absolutely be
sized for maximum consumption (as shown in the table).
If sufficient electrical energy is not available, an electronic en-
ergy consumption limiter can be activated from inside the
electronics box.
This operation can only be performed by authorized Jacuzzi
®
technicians and limits electricity consumption as follows:
J-210
J-315/325
- alternative consumption: 3.4 kW (when the pump is run at
high speed, the electric heater goes off).
J-235/245/275
J-335/345/355/365/375/385/J-LXL
J-415/465/480/495
J-575/585
- medium alternative consumption: 4,8 kW (1 pump by opera-
ting in high speed + electric heater).
- minimum alternative consumption: 3.9 kW (2 pumps opera-
ting at high speed, the heater turns off).
Weights
User safety
The system, if installed by qualified personnel, does not pres-
ent any hazard for the user. Safety is however also contingent
upon proper use, as set forth by the user's manual included
with the product. The user must contact qualified personnel for
special operations described in the manual.
It is important to make sure that personnel tasked to install
and manage the system are qualified as per legal requirements
in effect in the country where installation is carried out.
net
weight
average
fill
maximum
water
volume
total
max.
weight
kg litres litres kg
support
area
load concentrated
on support area
kg/m
2
J-210 ~ 239 ~ 908 ~ 1173 ~ 1412 ~ 2,48 ~ 569
J-235 ~ 326 ~ 1363 ~ 1741 ~ 2066 ~ 4,19 ~ 493
J-245 ~ 375 ~ 1363 ~ 1779 ~ 2153 ~ 4,19 ~ 513
J-275 ~ 366 ~ 1590 ~ 2006 ~ 2371 ~ 4,97 ~ 476
J-315 ~ 259 ~ 871 ~ 1060 ~ 1318 ~ 2,52 ~ 522
J-325 ~ 312 ~ 1363 ~ 1666 ~ 1976 ~ 3,33 ~ 592
J-335 ~ 342 ~ 1363 ~ 1703 ~ 2044 ~ 3,67 ~ 555
J-345 ~ 374 ~ 1401 ~ 1741 ~ 2114 ~ 3,67 ~ 574
J-355 ~ 379 ~ 1514 ~ 1855 ~ 2233 ~ 3,89 ~ 573
J-365 ~ 394 ~ 1666 ~ 1893 ~ 2285 ~ 3,89 ~ 587
J-375 ~ 407 ~ 1779 ~ 2196 ~ 2601 ~ 4,36 ~ 596
J-385 ~ 415 ~ 1893 ~ 2196 ~ 2610 ~ 4,36 ~ 598
J-LXL ~ 406 ~ 1476 ~ 1893 ~ 2298 ~ 3,69 ~ 621
J-415 ~ 265 ~ 871 ~ 1098 ~ 1362 ~ 2,46 ~ 552
J-465 ~ 411 ~ 1552 ~ 1931 ~ 2340 ~ 3,72 ~ 628
J-480 ~ 454 ~ 1817 ~ 2271 ~ 2724 ~ 4,48 ~ 607
J-495 ~ 517 ~ 1968 ~ 2347 ~ 2862 ~ 5,28 ~ 542
J-575 ~ 407 ~ 1685 ~ 2063 ~ 2470 ~ 4,16 ~ 593
J-585 ~ 407 ~ 1666 ~ 2044 ~ 2451 ~ 4,16 ~ 589
m
2
Power supply
(single-phase)
Tot. Consumption: electric hea-
ter + pump(s)
Voltage Hertz Ampere
kW
21
(k)
4,8
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
21
(k)
4,8
(j)
21
(k)
4,8
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
29
(k)
6,7
(j)
J-210 220-240 ~ 50
J-235 220-240 ~ 50
J-245 220-240 ~ 50
J-275 220-240 ~ 50
J-315 220-240 ~ 50
J-325 220-240 ~ 50
J-335 220-240 ~ 50
J-345 220-240 ~ 50
J-355 220-240 ~ 50
J-365 220-240 ~ 50
J-375 220-240 ~ 50
J-385 220-240 ~ 50
J-LXL 220-240 ~ 50
Ampere/kW Ampere/kW
(k): 230 V (single-phase)
(j): max. power absorption
Power supply
(single-phase)
J-415 220-240 ~ 50
J-465 220-240 ~ 50
J-480 220-240 ~ 50
J-495 220-240 ~ 50
Voltage Hertz
17
(k)
/3,8
(
j
)
12
(k)
/2,7
(
j
)
17
(k)
/3,8
(
j
)
12
(k)
/2,7
(
j
)
17
(k)
/3,8
(
j
)
12
(k)
/2,7
(
j
)
26
(k)
/6,0
(
j
)
12
(k)
/2,7
(
j
)
pump(s) electric
heater
J-575 220-240 ~ 50
J-585 220-240 ~ 50
17
(k)
/3,8
(
j
)
12
(k)
/2,7
(
j
)
17
(k)
/3,8
(
j
)
12
(k)
/2,7
(
j
)

Other manuals for Jacuzzi J-200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jacuzzi J-200 Series and is the answer not in the manual?

Jacuzzi J-200 Series Specifications

General IconGeneral
BrandJacuzzi
ModelJ-200 Series
CategoryHot Tub
LanguageEnglish

Related product manuals