Limiter
THD at Max. Output
Power
n/a n/a functional
Maximum Output Power
Maximum THD as a result of limiting.
Features
—
Volume pot Taper
(lin/log)
LOG
— functional
HP Speaker out functional Refer to filter section
Input Configuration
Line In & LFE YES — functional LR dual RCA jack
Spkr/Hi Level In YES — functional Spring type connector
Signal Sensing (ATO)
Auto-Turn-On YES functional Auto - on selection switch in Auto Bicolor LED (Green=signal/ red= No signal)
ATO Input test frequency 40 Hz functional “
ATO Line level in 5 mV functional "
ATO Level Speaker in 50 mV functional "
ATO Turn-on time
5
ms functional
Amp connected and AC on, then input signal
applied
Auto Mute/ Turn-OFF
Time
15
minutes
17 T before muting, after signal is removed Auto turn of time (T) must be 3>T<15
Minutes
Power on Delay time
0.1 sec. 5 AC Power Applied
Transients/Pops
ATO Transient 5 mV-peak 50
Turn-on Transient 2 Vpk-pk 2 @ Speaker Outputs AC Line cycled from OFF to ON
Turn-off Transient 2 Vpk-pk 2 @ Speaker Outputs AC Line cycled from ON to OFF
Efficiency
Efficiency 65 % 64 Nominal Line voltage 120 VAC / 230 VAC
Stand-by Input Power
15
Watts
18 @ nom. line voltage Auto turn of time (T) must be 3>T<15
Minutes
Power Cons. @ rated
power
76
Watts
80 @ nom. line voltage
75 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
functional
Direct short at output Amplifier should resume operation after short
circuit condition removal
Thermal Protection
YES
functional
@1/8 max unclipped Power IEC Noise
using driver load
Temperature rise in accessible metal parts
should not exceed 35K rise for 120v version
or 30K rise for European versions (refer to
requirements sheet).
Line Fuse Rating
US (120v) version Amps 0.6 Type-T or Slo Blo-250 V Internal fuse
EU Amps TBD Type-T or Slo Blo-250 V External fuse with UL/SEMKO rated holder
5