WRDB - GB
4
Information about the heater
1 Information about the heater
1.1 Category, type and approval no.
1.2 Technical identification code
W Water gas heater
R Proportional power adjustment
D Digital display
11 Capacity (l/min)
-2 Version 2
B Electronic ignition powered by 1.5 V batteries
23 Indicator number of natural gas H
31 Indicator number of LPG
S... Country code
1.3 Supplied materials
Gas heater
Attachment elements
Connection elements
Heater documentation
Two 1.5 V batteries type R
Rubber holders (LPG heaters).
1.4 Description of the heater
Operating convenience, as the heater is ready to oper-
ate by simply pressing a switch.
Heater for wall-mounting
Ignition by electronic device triggered when the
water valve opens
Gauge to display temperature, burner operation and
malfunctions
Temperature sensor to monitor the water tempera-
ture at the heater output
Great savings in comparison with conventional hea-
ters, due to the possibility of power adjustment and
no permanent pilot flame
Natural gas/LPG burner
Semi-permanent pilot burner which only functions
during the period between the opening of the water
valve and the ignition of the main burner
Heat exchanger without tin/lead covering
Water automatic in fibreglass-reinforced polyamide,
100% recyclable
Automatic adjustment of the water flow by means of
a device which permits a constant flow to be maintai-
ned in spite of variable pressure supplies
Gas flow adjustment proportional to the water flow to
maintain a constant high temperature.
Safety devices:
Ionisation probe to check for accidental extinction
of the burner flame
Combustion gases monitoring device which turns
off the heater in case of inadequate combusted
gas evacuation conditions
Temperature limiter which prevents overheating of
the heat exchanger
1.5 Special accessories
Conversion kit from natural gas to butane/propane
and vice-versa.
Model WRD 11/14/18 -2 B...
Category II
2H3+
Type B
11BS
Tab. 1
W R D 11 -2 B 23
31
S...
W R D 14 -2 B 23
31
S...
W R D 18 -2 B 23
31
S...
Tab. 2
0464

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Junkers miniMAXX WRD 18-2.B Series and is the answer not in the manual?

Junkers miniMAXX WRD 18-2.B Series Specifications

General IconGeneral
BrandJunkers
ModelminiMAXX WRD 18-2.B Series
CategoryGas Heater
LanguageEnglish

Related product manuals