7 Available signals
The following signals are available for this monitor.
Video signals
No. Signal name
Input terminal
VIDEO
(INPUT1, INPUT2)
COMPO./RGB
(Analog component/
analog RGB)
HD/SD SDI (IN 1, IN 2)*
1
(DT-V24L1D and
DT-V20L1D only)
DVI-D (HDCP)
(Digital component/digital
RGB)
1 NTSC
———
2PAL
———
3 SECAM
———
4 BW(50Hz/60Hz)
———
5 480/60i
√√
6 576/50i
√√
7 480/60p
8 576/50p
9 640480/60p
10 720/60p
√√
11 720/50p
√√
12 720/30p
√√
13 720/25p
√√
14 720/24p
√√
15 1080/60i
√√
16 1035/60i *
2
17 1080/50i
√√
18 1080/60p
19 1080/50p
20 1080/30p
√√
21 1080/25p
√√
22 1080/24p
√√
23 1080/30psF *
3
*
3
24 1080/24psF
√√
:
Acceptable
: Not acceptable
*
1
Compatible with EMBEDDED AUDIO
*
2
Displays the picture as 1080/60i, and “1080/60i” is displayed in the status display ( page 7).
*
3
“1080/60i” is displayed in the status display ( page 7).
Computer signals (preset)
DVI-D (HDCP) terminals
No. Signal name
Screen resolution
Horizontal
frequency (kHz)
Vertical
frequency (Hz)
Scan system
Horizontal Vertical
1 VGA60 640 480 31.5 59.9 Non-interlace
2 WVGA60 852 480 31.5 59.9 Non-interlace
3 SVGA60 800 600 37.9 60.3 Non-interlace
4 XGA60 1024 768 48.4 60.0 Non-interlace
5 WXGA (1280) 1280 768 47.8 60.0 Non-interlace
6 SXGA60 1280 1024 64.0 60.0 Non-interlace
7 SXGA+60 1400 1050 64.0 60.0 Non-interlace
8 SXGA+60* 1400 1050 65.2 60.0 Non-interlace
9 WSXGA+60 1680 1050 65.2 60.0 Non-interlace
10 UXGA60*
4
1600 1200 75.0 60.0 Non-interlace
11 WUXGA60*
4
1920 1200 74.0 59.9 Non-interlace
*
4
For DT-V20L1D and DT-V20L1: When No. 10 or 11 signal is input, thin lines will become obscured because their signal
resolution is higher than the screen resolution.
Specification of DVI-D (HDCP) terminal
Connect it to DVI-D output terminal on a personal computer.
Note for analog component/analog RGB signals
The monitor is compatible with G on sync, Y on sync and composite sync (Cs) signals. The monitor is not
compatible with separate sync (HS/VS) signals.
Note for computer signals
Non-preset signals may not be displayed normally even if its frequency is within the acceptable range.
When a preset signal is input, the signal format is displayed on the screen. For other signals, the resolution is
displayed.
Note for connections
Before making any connections, turn off all the equipment.
Use a cord whose plugs correctly match the terminals on this monitor and the equipment.
Plugs should be firmly inserted; poor connections could cause noise.
When unplugging a cord, be sure to grasp its plug and pull it out.
DO NOT connect the power cord until all connections are completed.
Refer also to the user manual of each piece of equipment.
Pin
No.
Input signal
Pin
No.
Input signal
Pin
No.
Input signal
1
T.M.D.S Data 2–
9
T.M.D.S Data 1–
17
T.M.D.S Data 0–
2
T.M.D.S Data 2+
10
T.M.D.S Data 1+
18
T.M.D.S Data 0+
3
T.M.D.S Data 2 shield
11
T.M.D.S Data 1 shield
19
T.M.D.S Data 0 shield
4
NC
12
NC
20
NC
5
NC
13
NC
21
NC
6
DDC Clock
14
+5 V Power
22
T.M.D.S Clock shield
7
DDC Data
15
GND
23
T.M.D.S Clock+
8
NC
16
Hot Plug Detect
24
T.M.D.S Clock–
DT-V2420L1D_UA.indd 9DT-V2420L1D_UA.indd 9 06.11.7 9:16:24 AM06.11.7 9:16:24 AM

Other manuals for JVC DT-V24L1U

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JVC DT-V24L1U and is the answer not in the manual?

JVC DT-V24L1U Specifications

General IconGeneral
BrandJVC
ModelDT-V24L1U
CategoryMonitor
LanguageEnglish

Related product manuals