T 201
4. Maintenance and
Servicing
Attention:
Always remove the mains plug from the sok-
ket before any servicing work
When repair work is necessary please only
use original Kärcher replacement parts. They
alone will ensure that the appliance is always
reliable and ready to operate.
At regular intevals and after finishing work
clean the appliance
clean the rubber seals on the lid
Check
Pipes and leads
If suction power is diminishing
Change motor protection filter.
Important note: take care for right seat of
motor protection filter (Risk of damage of suc-
tion turbine)
5. Malfunction Help
Malfunction Cause Solution
Motor (suction turbine)
won‘t start.
No electric voltage Check fuse, cable, plug and socket
Suction insufficient Paper filter bag is full
Nozzle, suction pipe or suction
tube is blocked.
Change paper filter bag
Check, remove blockage
Dust comes out during
suction.
Filter bag not properly inserted or
defective
Check filter insert or change filter
Motor (suction turbine)
switches off.
Heat controller switches off motor
due to danger of overheating
Switch machine off.
Change filter, clean motor protection
filter and suction pipe.
After 20 min the unit will start up
again.
All checks and interventions on electrical parts must be carried out by an expert. If malfunctions
continue contact the Kärcher Customer Service Centre.