4.2.4 Additional precharging resistor at master-slave operation
The external precharging resistor is required from housing size 29. The re-
sistor is used for additional energy input and limitation of the charging cur-
rent. The external resistor is switched into phase L1 at the precharge input
(=> „Circuit example for the master-slave operation with AIC/LCL lter and common mode
lter“).
Material number Resistance Rv Power Voltage
0090013-0048 5.8Ω 165 W 1100 V
4.3 Dimensions and weights
The COMBIVERT F5-AIC have identical housings with the COMBIVERT F5 drive con-
verters. Dimensions, weights and terminal descriptions can be found in the following
instruction manuals:
Size Housing Instruction manual
14 E Housing E
16 G Housing G
18 H Housing H
20, 22 R Housing R
24, 26, 27 U Housing U
28, 29, 30, 33, 34, 38 P Housing P
Table 13: Dimensions and weights
Theinstructionmanualscanbefoundinthespeciedlinksorunder
www.keb.de/de/service/downloads.
33
UNIT DATA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT 16F5 Series and is the answer not in the manual?

KEB COMBIVERT 16F5 Series Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT 16F5 Series
CategoryInverter
LanguageEnglish

Related product manuals