Programmable Power Supplies Verification and Adjustment Manual Section 5:
Verification test record forms
077104802 / November 2016 5-3
Constant current tests:
Current programming
and measurement
Model Minimum
specifications
Results Maximum specifications
Minimum current out
30-36 -30 mA +30 mA
30-72 -60 mA +60 mA
30-108 -100 mA +100 mA
Measurement accuracy
30-36 -40 mA +40 mA
30-72 -70 mA +70 mA
30-108 -100 mA +100 mA
Rated current out
30-36 35.934 A 36.066 A
30-72 71.898 A 72.102 A
30-108 107.862 A 108.138 A
Measurement accuracy
30-36 35.924 A 36.076 A
30-72 71.858 A 72.142 A
30-108 107.79 A 108.21 A
CC load regulation Model Minimum
specifications
Results Maximum specifications
30-36
-41 mA
+41 mA
30-72
-77 mA
+77mA
30-108
-113 mA
+113 mA
CC line regulation Model Minimum
specifications
Results Maximum specifications
30-36
-41 mA
+41 mA
30-72
-77 mA
+77mA
30-108
-113 mA
+113 mA

Other manuals for Keithley 2260B-80-13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2260B-80-13 and is the answer not in the manual?

Keithley 2260B-80-13 Specifications

General IconGeneral
BrandKeithley
Model2260B-80-13
CategoryPower Supply
LanguageEnglish

Related product manuals