POWER FAILURE
When power to the freezer is restored after the occur-
rence of a power failure, the "Power Loss" LED will be
illuminated.
If the internal temperature of the freezer has risen to
a temperature greater than 23°F (-5°C), the "Hi Temp"
display indicator will also be illuminated and there will
be an audible beep every five seconds. Press the Alarm
Reset button to turn the audible alarm (beep) off.
If this condition persists, the "Duration" indicator will
also be illuminated and the display will show how many
hours (up to a period of 48) the internal temperature has
been above 23°F (-5°C). Food quality is considered to be
impaired at temperatures greater than 23°F (-5°C). It is left
to the user's discretion to decide how to best manage the
contents within the freezer.
Door Ajar Power Loss
H01dFor_fC
Quick Temp Alarm
Freeze Display Reset
f
Figure 7
SYSTEM ERROR ALARMS
If "E7", "E8", or "E9" are shown on the display every half
second and the control panel beeps every five seconds,
call service repair to correct the problem. Press the Alarm
Reset button to turn the audible alarm (beep) off. Until
changes are made, freezer will continue to run.
ALARM FUNCTION TABLE
Except during power loss, the alarm indicators illuminate
whenever there is an alarm status.
Display Status
Cabinet
temperature
setting is
displayed
Alternating "E'
and "7", "8" or "9"
every half second
Control panel
beeps every 5
seconds. "Door
Ajar" LED is lit.
Control panel
beeps every 5
seconds. "Hi
Temp" LED is lit.
Function
Normal operation
Operational error
Door Ajar
Freezer
temperature too
high.
Response
None
Contact service
technician.
Close door. Press
Alarm Reset
to mute audible
alarm (beep).
Contact service
technician. Press
Alarm Reset
to mute audible
alarm (beep).
Press Alarm
Reset button.
"Power A power failure
Loss" LED is occurred.
illuminated.
Display off. Power failure Reconnect power
supply.