KENMORE INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
An extension cord must not be used
with this appliance. Such use may result in a re,
electrical shock, or other personal injury.
armored cable extending from this appliance should
Figure 2 with as much slack as possible remaining in
Observe all governing codes and local ordinances.
Unpacking Instructions
Cooktop
Cleaning and Maintenance section in the Use and
Care Guide.
Electrical Connection
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
follows.
Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor exible cable. If connection is made
to aluminum house wiring, use only special connectors
which are approved for joining copper and aluminum
wires in accordance with the National Electrical Code
and local codes and ordinances. Improper connection
of aluminum house wiring to copper leads can
result in a short circuit or re. Follow the connector
manufacturer recommended procedure closely.
a frame connected green or bare copper grounding
wire.
DO NOT ground to a gas supply
pipe. DO NOT connect to electrical power supply
until appliance is permanently grounded. Connect the
ground wire before turning on the power.
Important Notes to the Installer
instructions before installing the cooktop.
number and product code.
Important Note to the Consumer
future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Be sure your cooktop is installed and grounded
properly by a qualied installer or service technician.
This cooktop must be electrically grounded in
accordance with local codes or, in their absence, with
the National Electrical Code ANSI/NFPA No. 70—latest
edition in the United States, or with CSA Standard
C22.1, Canadian Electric Code, Part 1, in Canada.
The electrical power to the cooktop
must be shut o while line connections are being made.
Failure to do so could result in serious injury or death.
Provide Electrical Connection
connected in the junction box.
Electrical Requirements
Observe all governing codes and local ordinances.
required on a separate circuit fused on both sides
NOTE: