SAFETY AND CONTROL DEVICE CONNECTOR
COM Common for the FLASH-IND-LED inputs
FLASH Flashing light output 24Vdc (without regulation), maximum 25W
IND
IND output for barrier open indicator light 24 Vdc not regulated 4W MAX / Electric lock output 12Vac, 15VA maximum
selectable with parameter
IN.D.
LED
Courtesy light output 24Vdc (without regulation), maximum 25W, controllable also via radio ON-OFF command (radio
channel 4 selecting fC.y. = 2, tC.y. = 0)
24 VAC Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
24 VAC Accessories power supply 24 Vac without regulation, 200 mA (with battery operation output not active)
NEG Accessories power supply negative
PH-POW
Photocells PH1 and PH2 power supply positive; phototest can be selected with parameter
tp.h. 24 Vdc, 250 mA
STOP
STOP safety device, NC contact between STOP and STOP (warning, with dip switch 1 ON the safety device input is
o󰀨). This input is classied as a safety device; the contact can be deactivated at any time, cutting out the automation
system and disabling all functions, including Automatic Closure.
Safety sensor edge, ON/OFF, NC contact or resistive 8K2 between STOP and STOP.
Input selectable with parameter
Ed.m.
PH2
Photocells (opening), NC contact between PH2 and COM (warning, with dip switch 2 ON the PHOTOCELL 2 safety
device input is o󰀨). The photocell is tripped at any time during opening of the automation system, halting operation
immediately; the automation system will continue opening when the contact is restored. In the event of intervention on
closure (parameter
Ph.2. = 0) the device stops and on release re-opens.
PH1
Photocells (closing), NC contact between PH1 and COM (warning, with dip switch 3 ON the PHOTOCELL 1 safety
device input is o󰀨) The photocell is tripped at any time during closing of the automation system, halting operation im-
mediately and reversing the travel direction.
OPEN
OPEN command NO contact between OPEN and COM
Contact for the HOLD-TO-RUN function. The barrier OPENS as long as the contact is held down
CLOSE
CLOSE command NO contact between CLOSE and COM
Contact for the HOLD-TO-RUN function. The barrier CLOSES as long as the contact is held down
SBS
STEPPING command NO contact between SBS and COM
Open/Stop/Close/Stop command, or as set in the software
COM Common for the PH2-PH1-OPEN-CLOSE-PAR-SBS inputs
SHIELD Antenna - shield -
ANT Antenna - signal -
6.5 - Display during normal operation
In “NORMAL OPERATING MODE”, i.e. when the system is powered up normally, the 3-gure LCD display shows the following status messages:
In addition, the dots between the gures illustrate the status of the limit switches, as described in greater detail below:
n
MESSAGES MEANING
-.-
Limit switch CLOSED (one dot between the two lines)
tC.
Limit switch OPEN (a point to the right)
SO
No limit switch active (no dots present)
MESSAGES MEANING
--
Barrier closed or switch-on after shutdown
OP
Barrier opening
CL
Barrier closing
SO
Barrier stopped during opening
SC
Barrier stopped during closure
F1
Photocell 1 tripped
F2
Photocell 2 tripped
HA
Barrier stopped by external event
ALI
Re-alignment procedure
oP
Barrier stopped without automatic reclosure
-tC
Barrier open with timed reclosure
Flashing dash counting in progress
Dash replaced by gures 0..9 countdown (last 10s)
L--
Learning started on limit switch (move the barrier o󰀨 the limit switch to continue the learning procedure) or
learning stopped due to trip of safety device or motor inversion.
LOP
Learning opening
LCL
Learning closure