42
EVENT DESCRIPTION
KEY TO MAIN CONTROL
FLASHING LIGHT AND KEY LEDS
CONTROL UNIT
opening Barrier opening
closure Barrier closing
automatic closure Barrier open with timed reclosure active
stop during closure Barrier stopped during closure
stop during opening Barrier stopped during opening
open Barrier completely open without automatic reclosure
closed Barrier completely closed
programmation During the programming phase 2 quick ashes + pause + 1 ash
obstacle M1 Motor 1 obstacle detected 4 quick ashes + pause, 3 times
photo 1! Photocell 1 tripped 2 quick ashes + pause, 3 times
photo 2! Photocell 2 tripped 2 quick ashes + pause, 3 times
sensitive edge! Sensitive edge tripped 5 quick ashes + pause, 3 times
realignment Realignment after a manual release
phototest error Phototest error detected 3 quick ashes + pause, 3 times
encoder error Encoder error detected 7 quick ashes
Malfunctions
This section lists a number of malfunctions which may occur.
SURGE OVERLOAD ALARM The motors current drawdown has increased very quickly
EOL
1. The barrier has struck an obstacle.
2. Friction on runners or rack (see motor current [A]).
SAFETY EDGE ALARM The control unit has received a signal from the safety edge
EED
1. The safety edge has been pressed.
2. The safety edge is not connected correctly.
LIMIT SWITCH ALARM The limit switches are not working properly
ELS
1. The limit switches are damaged.
2. The limit switches are not connected.
3. Check the travel time which has passed without tripping of the limit switches.
PHOTOCELL ALARM/SAFETY EDGE Phototest fail outcome.
EPH
1. Check the photocell and the safety edge connections.
2. Check that the photocells and the safety edg are operating correctly.
ENCODER ALARM Encoder encoder (only if encoder is present)
EEN
1. Check the encoder connections.
2. Check that the encoder are operating correctly.
After eliminating the cause of the alarm, to delete all errors simply
press the “DOWN -” key or press the SBS (STEPPING) command
The display returns to the normal screen.
DISPLAY MEANING
Status display (--, OP, CL, SO, ecc..) Description of the control unit (--, OP, CL, SO, ecc..)
Maneuvers performed Counter displays alternating the thousands (without dots) and the units (with dots).
Motor current [A] Current absorbed by the motor
Press “UP“ to read the following parameters on display.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation ALT3KF Series and is the answer not in the manual?

Key Automation ALT3KF Series Specifications

General IconGeneral
BrandKey Automation
ModelALT3KF Series
CategoryOther
LanguageEnglish

Related product manuals