EasyManuals Logo
Home>Key Automation>Control Unit>CT102 24

Key Automation CT102 24 Instructions And Warnings For Installation And Use

Key Automation CT102 24
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
25
EN
25
   MIN MAX 
1
TCL
Automatic reclosure time (0 = off) 0 0 900 s
2
ttr

(0 = off)
0 0 30 s
3
SEI
Sensitivity on obstacles
0 = Maximum impact force
10 = Minimum impact force
3 0 10
4
SFO
Motor speed during opening
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
5
SSO
Motor speed during opening deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5
6
SFC
Motor speed during closing
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
4 1 5
7
SSC
Motor speed during closing deceleration phase
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
1 1 5
8
SBS




3 = Apartment block – timer
4 = Apartment block with immediate reclosure
0 0 4
9
LSI
Deceleration distance
0 to 100 = Motor deceleration percentage during
opening and closure
20 0 100 %
10
BlT
Post blackout procedure
0 = No action, remains stationery
1 = Closure
0 0 1 s
11
SBY
Energy saving: enables photocell switch-off when gate
is closed
0= disabled
1= enabled
0 0 1

Other manuals for Key Automation CT102 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation CT102 24 and is the answer not in the manual?

Key Automation CT102 24 Specifications

General IconGeneral
BrandKey Automation
ModelCT102 24
CategoryControl Unit
LanguageEnglish

Related product manuals