27
EN
6 - FURTHER DETAILS - ADVANCED MENU
PARAMETS DESCRIPTION DEFAULT MIN MAX UNIT TYPE
1
SP.h.
Use of PHOTO1 when starting from closed
0 = PHOTO1 is checked
1 = The gate starts even with PHOTO1 excited
1 0 1
SL/BA/
OH
2
Ph.2.
Use of PHOTO2
0 = Enabled during both opening and closing AP/CH
1 =Only enabled during opening AP
1 0 1
SL/BA/
OH
3
tP.h.
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
0 0 3
SL/BA/
OH
4
Ed.m.
STOP input selection
0 = STOP contact (NC)
1 = Resistive safety edge (8k2)
2 = Contact safety edge (NC)
0 0 2
SL/BA/
OH
5
iE.D.
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
0 0 1
SL/BA/
OH
6
tE.D.
Edge test
0 = off
1 = on
0 0 1
SL/BA/
OH
7
LP.o.
Pedestrian opening 50 10 100 % SL
8
TP.C.
Time for automatic closure from pedestrian opening (0=off) 0 0 900 s SL
9
FP.r.
Flashing light output setup
0 = Steady
1 = Flashing
2 = Two-colour LED strip for barrier (MODE 1)
- gate closed steady red
- gate open LEDs off
- during opening ashing green
- during closing ashing red
- stopped not on limit switch ashing red
3 = two-colour LED strip for barrier (MODE 2)
- gate closed steady red
- gate open steady green
- during opening ashing green
- during closing ashing red
- stopped not on limit switch ashing red
N.B.: if this parameter is set as 2 or 3, the settings of
parameter .D. will be ignored.
If this parameter is set as 2 or 3, the ashing light and gate
open light outputs will be used for operation with the LED strip
1 0 3
SL/BA/
OH
10
tP.r.
Pre-ashing time (0 = off) 0 0 20 s
SL/BA/
OH
11
FC.Y.
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
0 0 2
SL/BA/
OH
12
tC.Y.
Courtesy light on time 0 0 900 s
SL/BA/
OH
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu.
To access the ADVANCED menu, press the MENU key and hold it
down for 5 seconds.
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU.
LEGENDA:
SL= sliding gate
BA= barrier
OH= up-and-over door
N.B. Some default functions/display items may vary with respect to
the type of motor selected.
n

Other manuals for Key Automation CT102 24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation CT102 24 and is the answer not in the manual?

Key Automation CT102 24 Specifications

General IconGeneral
BrandKey Automation
ModelCT102 24
CategoryControl Unit
LanguageEnglish

Related product manuals