Recommended Installation Locations
CO alarms should be mounted in
or near bedrooms and living areas.
It is recommended that you install
a Kidde CO alarm on each level of
your home.
When choosing your installation
locations, make sure you can hear
the alarm from all sleeping areas.
If you install only one CO alarm in your home, install it near bedrooms
to increase your chances of hearing the alarm as you sleep, not in the
basement or furnace room.
• When wall mounting, place out of reach of children. Under no
circumstances should children be allowed to handle the CO alarm.
• Placing the alarm at eye level allows for optimum monitoring of the
digital display.
3. Installation Locations
DINING
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
Recommended Locations
Temperature:
Operating Range: 0° to 40°C
Humidity:
Operating range: Up to 90% (non-condensing)
Audible Alarm:
85+ dB at 1 metre @ 3.4±0.5 KHz pulsing alarm
Sensor:
Electrochemical
Power:
Sealed-in Lithium batteries
Accuracy of Digital Display: (Model 8LLDCO Only)
30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10°
F), atmospheric pressure +/- 10% and 40% +/- 3% relative humidity.
Display readings may vary slightly depending on changes in the ambient
condition (temperature, humidity) and the condition of the sensor.
Alarm Response Times:
30 PPM = no alarm in 120 minutes., 50 PPM = Must alarm in 60-90 minutes.,
100 PPM = Must alarm in 10-40 minutes., 300 PPM = Must alarm within 3minutes.
2. Product Features and Specifications