23
Use the same LLC for refilling.
【Attended operations】
● Add anti-rustiness & anti-freezing liquid when handling cooling water. In the cold winter,
frozen cooling water expands and damages parts in the cooling water pipe. Exclusive use of
fresh water and rustiness of water pipe lead to bad cooling effect.
● If the generator is used in the hot area without freezing risk, it is also recommended to add
specified anti-freezing liquid to avoid rustiness.
● Little anti-freezing liquid may affect cooling effect or lead to rustiness when temperature falls
down.
Thick anti-freezing liquid also affects cooling effect for engine.
Mix according to proper combination ratio.
(2) Anti-freezing liquid
It is no need to add more anti-rustiness agent because anti-freezing liquid combines the function
of anti-rustiness. Life of anti-freezing liquid is one year. Combination ratio: 30%-55%.
Lowest temperature ℃ <-15 -20 -25
Combination ratio ℃ 30 40 50
(3) If use the marketable anti-freezing liquid
Select the anti-rustiness& anti-freezing liquid.
Observe the combination ratio specified by the manufacturer.
Replace the anti-freezing liquid once per year.
5.4 Operation of battery
As storage battery easily produces inflammable gas; incorrect operation sometimes may lead to
explosion or serious human injury.