CARE AND MAINTENANCE
All maintenance should only be carried out by a qualied service technician.
Cleaning
Before cleaning or performing any maintenance, remove the battery pack. For safe and proper
operation, always keep the tool and its ventilation slots clean.
Always use only a soft, dry cloth to clean your circular saw; never use detergent or alcohol.
TROUBLESHOOTING
WARNING
Turn the switch to the “OFF” position and remove the battery before performing troubleshooting
procedures.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Tool does not work. Low battery charge. Charge the battery pack.
Cut binds, burns,
stalls motor when
ripping.
1. Dull blade with improper
tooth set.
2. Blade binds.
3. Improper workpiece
support.
1. Discard the blade and use a
different blade.
2. Reassemble the blade and tighten
the blade bolt according to this
manual.
3. Clamp or support workpiece
properly according to this manual.
Saw vibrates or
shakes
1. Blade out of balance.
2. The blade is not
installed properly.
3. Improper workpiece
support.
1. Discard the blade and use a
different blade.
2. Remove the blade and reinstall it.
Ensure no part was missed.
3. Clamp or support workpiece
properly according to this manual.