Engine Cranks But Does Not Start
CAUTION: Failure to change the fuel system filter as recommended
can result in premature failure of fuel injection system components.
WARNING: Use extreme care when changing the fuel filter. Gasoline
is highly flammable and under pressure. It should not be exposed to open
flame, sparks, or hot engine components. Allow the engine to cool to
ambient temperature prior to changing fuel filters.
WARNING: Fuel is under HIGH pressure, consult equipment dealer
before servicing fuel system.
WARNING: The bilge can accumulate explosive fumes. The bilge
Blower will evacuate the fumes. The bilge Blower must be run for a
minimum of 10 minutes prior to cranking the engine.
1. Check fuel pressure
2. Check fuel tank level
3. Check for signs of a fuel leaks
4. Check the fuel supply.
5. Check fuel supply valve – the valve should be open.
6. Check fuel lines.
Inspect for crimped, kinks, blockage or any disconnected lines.
Inspect for any leakage (leaks may allow air in the lines blocking fuel flow.)
Follow and repair any leaks before continuing.
Contact your service dealer for more advanced diagnosis
Check fuel pressure (service dealer)
Clean up any fuel spills or leaks prior to attempting to start the engine.