TP-7044 6/23 17
Section 2. Operation
2.1 Prestart Checklist
WARNING
Carbon monoxide.
Can cause severe nausea, fainting, or death.
The exhaust system must be leakproof and routinely inspected.
Operating the generator set. Carbon monoxide can cause severe nausea, fainting, or death. Be especially careful if
operating the generator set when moored or anchored under calm conditions because gases may accumulate. If operating the
generator set dockside, moor the craft so that the exhaust discharges on the lee side (the side sheltered from the wind). Always
be aware of others, making sure your exhaust is directed away from other boats and buildings.
DANGER
Hazardous voltage. Moving parts.
Will cause severe injury or death.
Operate the generator set only when all guards and electrical enclosures are in place.
Servicing the generator set when it is operating. Exposed moving parts will cause severe injury or death. Keep hands,
feet, hair, clothing, and test leads away from the belts and pulleys when the generator set is running. Replace guards, screens,
and covers before operating the generator set.
To ensure continued satisfactory operation perform the following checks or inspections before or at each startup, as designated,
and at the intervals specified in the service schedule. In addition, some checks require verification after the unit starts.
Air Inlets. Check for clean and unobstructed air inlets.
Battery. Check for tight battery connections. Consult the battery manufacturer’s instructions regarding battery care and
maintenance.
Coolant Level. Check the coolant level according to the cooling system maintenance information.
Drive Belts if equipped. Check the belt condition and tension of the water pump belt.
Exhaust System. Check for exhaust leaks and blockages. Check the silencer and piping condition and check for tight exhaust
system connections.
Inspect the exhaust system components (exhaust manifold, mixing elbow, exhaust line, hose clamps, silencer, and exhaust
outlet) for cracks, leaks, and corrosion.
Check the hoses for softness, cracks, leaks, or dents. Replace the hoses as needed.
Check for corroded or broken metal parts and replace them as needed.
Check for loose, corroded, or missing clamps. Tighten or replace the hose clamps as needed.
Check that the exhaust outlet is unobstructed.
Visually inspect for exhaust leaks (blow by). Check for carbon or soot residue on exhaust components. Carbon and
soot residue indicates an exhaust leak. Seal leaks as needed.
Ensure that the carbon monoxide detector(s) is (1) in the craft, (2) functional, and (3) energized whenever the generator
set operates.
For your safety: Never operate the generator set without a functioning carbon monoxide detector(s) for your safety and
the safety of others on your vessel.
Fuel Level. Check the fuel level and keep the tank(s) full to ensure adequate fuel supply.

Table of Contents

Other manuals for Kohler 17EFKOZD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 17EFKOZD and is the answer not in the manual?

Kohler 17EFKOZD Specifications

General IconGeneral
BrandKohler
Model17EFKOZD
CategoryPortable Generator
LanguageEnglish

Related product manuals