TP-6591 10/13 21Section 2 Operation
Warnings
Code Description
Sensing
Mechanism
Active
State
Inhibit
Time
Delay
Time
Default
Setting
Check
Hi CO:
sensor
High CO from
sensor. Fault
code is displayed
ifthepresenceof
CO is detected.
W arning occurs if
the sensor detects
acceptable but
increasing CO
levels.
Pulsed signal 10 Hz 0sec 10 sec N/A Ensure windows are open for proper
ventilation.
Operate the blower to expel
dangerous fumes.
Move the vessel away from other
vessels (as another vessel may be the
source for the presence of the CO).
Check the generator exhaust system
(see Section 3.6).
Contact an authorized
distributor/dealer for service.
CO sensr err Faulty CO sensor Pulsed signal 5Hz 0sec 10 sec N/A Replace the CO sensor. Contact an
authorized distributor/dealer for service.
Low oil pres Low oil pressure Digital Grounded 30 sec 0sec 5psi Check for leaks in the lubrication
system.
Check t he oil level and add oil if the
level is low.
Hi eng temp High engine
temperature
ECM data Above setting 30 sec 0sec 210_ F Check for a low engine coolant level.
Check seawater system for reduced
flow.
NOTE: Allow the generator set to
cool down before checking.
Maint req Maintenance
required
Clock N/A 0sec 0sec N/A
Figure 2-7 Advanced Digital Control II Warnings
In addition to the fault shutdowns and warnings included
in Figure 2-6 and Figure 2-7, other fault
shutdowns/warnings may occur (see Figure 2-8).
Contact an authorized Kohler distributor/dealer for
additional diagnostics.
Text Displayed
Description
Fault Shutdowns:
TPS input hi Throttle Position Sensor Input High
TPS range hi Throttle Position Sensor Range High
TPS range lo Throttle Position Sensor Range Low
TPS input lo Throttle Position Sensor Input Low
ETC sticking Electronic Throttle Control Sticking
ETC driver Electronic Throttle Control Driver Fault
MAP input hi Map Sensor Input High
MAP input lo Map Sensor Input Low
Trans hi XDRP Sensor Input High
Trans lo XDRP Sensor Input Low
IAT input hi Intake Air Temp. Input Sensor High
IAT input lo Intake Air Temp. Input Sensor Low
ECT input hi Coolant Sensor Input High
O2 input hi Oxygen Sensor Input High
O2 input lo Oxygen Sensor Input Low
O2 adapt O2 Adapt Limit Fault
CAN loss CAN Receive Message Fault
Overload Power Limit Shutdown
Warnings:
EST 1 Low Spark 1 Timing Low
EST 1 High Spark 1 Timing High
EST 2 Low Spark 2 Timing Low
EST 2 High Spark 2 Timing High
Injector Injector Fault
Oil sens err Oil Pressure Sensor
ETC s pring Electronic Throttle Control Spring Test Failed
ECT input lo Coolant Sensor Input Low
O2 sens open O2 Open Circuit
O2 limit err O2 Limit Error
Starter Starter Fault
Overload Power Limit Warning
Figure 2-8 Fault Shutdowns/Warnings