5.35
Section 5
EFI Fuel System
5
Code: 0563
Component: System Voltage
Fault: System Voltage High
Condition: Faulty voltage regulator or shorted
connection.
Possible Causes:
1. Faulty Recti er-Regulator
2. Bad Stator.
3. Bad Ba ery.
Code: 61
Fault: End of Code Transmission
Troubleshooting Flow Chart
The following ow chart provides an alternative
method of troubleshooting the EFI system. The chart
will enable you to review the entire system in about
10-15 minutes. Using the chart, the accompanying
diagnostic aids (listed a er the chart), and any
signaled fault codes, you should be able to quickly
locate any problems within the system. See Figure
5-30.