VM-4DKT Quick Start
P/N:
2900- 3015 44 QS
Rev:
1
Scan for full manual
Step 1: Check what’s in the box
VM-4DKT 1:4 4K HDMI/DGKAT Distribution Amplifier Transmitter
4 Rubber feet
1 Quick start guide
1 Power cord and adapter
IMPORTANT NOTICE!
We highly recommend using only Kramer UNIKAT cables with these products. If using 3
rd
party shielded CAT-6A cables, both ends of the
shield must be soldered to the connectors for the products to function properly. Do not use any jumpers, unshielded wall plates or mid-
span cable connections. These extenders are not compatible with HDBaseT technologies. Prior to signal extension, ensure that the
extension line cable is lying straight and not coiled.
Step 2: Get to know your VM-4DKT
#
Feature
Function
1
STATUS LED
Red Power up.
Green Power is on.
2
ACTIVE EDID LED
The LED color indicates the active EDID type. When flashing, the state is in the
process of being activated.
Yellow Default EDID.
Blue Output-acquired EDID.
Green Custom EDID.
3
INPUT LED
On Input signal detected.
Flashing Source connected, but no signal detected.
4
HDMI IN Connector
Connect to an HDMI source.
5
LOOP Connector
Connect to a local HDMI display.
6
DGKAT2 OUTPUTS Connectors (x4)
Connect to a DGKat-2.0 receiver (for example, PT-872xr) using twisted pair cable.
7
SERVICE 3-pin terminal block
Connect to a serial controller.
8
SETUP DIP-switches
Sets the device behavior (see Step 6: Operate VM-4DKT).
9
Fan Vent
For heat ventilation.
10
12V DC Power Connector
Connect the 12V DC power adapter into the device and then connect it to the
mains.
Step 3: Mount VM-4DKT
Install VM-4DKT using one of the following methods:
Attach the rubber feet and place the unit on a flat
surface.
Ensure that the environment (e.g., maximum ambient temperature & air flow) is
compatible for the device.
Avoid uneven mechanical loading.
Appropriate consideration of equipment nameplate ratings should be used for avoiding
overloading of the circuits.
Reliable earthing of rack-mounted equipment should be maintained.
Maximum mounting height for the device is 2 meters.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kramer VM-4DKT and is the answer not in the manual?

Kramer VM-4DKT Specifications

General IconGeneral
BrandKramer
ModelVM-4DKT
CategoryAmplifier
LanguageEnglish

Related product manuals